PSEN cs5.11n
Operating Manual PSEN cs5.11n
1004126-EN-03
14
Connection to evaluation devices
Make sure that the selected evaluation device has the following properties:
}
2-channel with feasibility monitoring
}
OSSD signals are evaluated
Single connection
CAUTION!
Do not connect the signal output to 0 V!
If the signal output Y32 is connected to 0 V, the safety switch may be dam-
aged as a result. Connect the signal output Y32 to a consumer, e.g. to the
input on a control system, or leave the signal output unconnected. Also note
the max. current (see
Technical details [
22]
).
Actuator
Receiver
Evaluation device
Connection to Pilz evaluation devices
The safety switch PSEN cs5.11n can be connected to Pilz evaluation devices, for example.
Suitable Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
}
PNOZpower for safety gate monitoring
}
PNOZsigma for safety gate monitoring