Fig.: Applying the screw covers [1] and [3] on the actuator
Procedure:
1. Drill holes (for M4 screws) in the mounting surface to secure the actuator and sensor
(see
Dimensions in mm [
20]
).
2. Use a screw to fix the sensor to the mounting surface.
Make sure that the square marking on the sensor can be operated using the actuator
from the right side.
3. Do not fully tighten the second screw on the safety switch.
4. Use a screw to fix the actuator to the mounting surface.
Make sure that the actuator with the triangle marking points towards the triangle mark-
ing on the sensor.
5. Do not fully tighten the second screw on the actuator.
6. Align the safety switch and tighten the screws.
7. Align the actuator and tighten the screws.
Use in operating heights higher than 2000 m above sea level
When using the PSEN cs5.11n note the reduced max. ambient temperature of +60 °C at a
height of 2000 m to 4000 m.
Adjustment
}
The stated operating distances (see
Technical details [
22]
) only apply when the
safety switch and actuator are installed facing each other in parallel. Operating dis-
tances may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
Operating distances [
9]
and
Lateral and vertical offset [
11]
).