PSEN cs5.11n
Operating Manual PSEN cs5.11n
1004126-EN-03
24
Mechanical data
Operating distances when the actuator approaches
square marking
Assured operating distance Sao
8 mm
Assured release distance Sar
20 mm
Typical operating distance So
11 mm
Typical release distance Sr
14 mm
Typical hysteresis
2 mm
Min. distance between safety switches
250 mm
Sensor flush installation in accordance with EN
60947-5-2
Yes, follow installation guidelines
Connection type
M12, 5-pin male connector
Material
PA+GF, PBT, polycarbonate
Max. torque setting for fixing screws
1 Nm
Dimensions
Height
26,4 mm
Width
101,6 mm
Depth
19 mm
Actuator dimensions
Height
18 mm
Width
90 mm
Depth
19 mm
Weight of safety switch
75 g
Weight of actuator
60 g
Weight
135 g
Where standards are undated, the 2015-11 latest editions shall apply.
Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
Mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
2-ch. OSSD
PL e
Cat. 4
SIL CL 3
9,56E-10
–
8,51E-06
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.