Pilz PNOZ m ES EtherNet/IP Скачать руководство пользователя страница 10

Safety

Operating Manual PNOZ m ES EtherNet/IP
1003387-EN-05

10

3.2

System requirements

Please refer to the "Product Modifications PNOZmulti" document in the "Version overview"
section for details of which versions of the base unit and PNOZmulti Configurator can be
used for this product.

3.3

Safety regulations

3.3.1

Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.

A competent person is someone who, because of their training, experience and current pro-
fessional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.

It is the company’s responsibility only to employ personnel who

}

Are familiar with the basic regulations concerning health and safety / accident preven-
tion,

}

Have read and understood the information provided in this description under "Safety",

}

And have a good knowledge of the generic and specialist standards applicable to the
specific application.

3.3.2

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended,

}

Damage can be attributed to not having followed the guidelines in the manual,

}

Operating personnel are not suitably qualified,

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

3.3.3

Disposal

}

When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).

3.3.4

For your safety

The unit meets all the necessary conditions for safe operation. However, you should always
ensure that the following safety requirements are met:

}

This operating manual only describes the basic functions of the unit. The expanded
functions are described in the PNOZmulti Configurator's online help. Only use these
functions once you have read and understood the documentations.

}

Do not open the housing or make any unauthorised modifications.

}

Please make sure you shut down the supply voltage when performing maintenance
work (e.g. exchanging contactors).

Содержание PNOZ m ES EtherNet/IP

Страница 1: ...PNOZ m ES EtherNet IP Operating Manual 1003387 EN 05 Configurable safe small controllers PNOZmulti 2...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...0 3 3 4 For your safety 10 Section 4 Function description 11 4 1 Operation 11 4 2 Data exchange 11 4 3 Input and output data 11 4 4 Block diagram 13 Section 5 Installation 14 5 1 General installation...

Страница 4: ...Contents Operating Manual PNOZ m ES EtherNet IP 1003387 EN 05 4 Section 8 Technical Details 23 Section 9 Order reference 26 9 1 Product 26 9 2 Accessories 26...

Страница 5: ...tion that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicat...

Страница 6: ...Introduction Operating Manual PNOZ m ES EtherNet IP 1003387 EN 05 6 INFORMATION This gives advice on applications and provides information on special fea tures...

Страница 7: ...onfigurator Connection for EtherNet IP as adapter Transmission rate 10 MBit s 10BaseT and 100 MBit s 100BaseTX Status indicators for communication and for errors 128 virtual inputs and outputs on the...

Страница 8: ...387 EN 05 8 2 3 Front view Legend X1 X2 EtherNet IP Interfaces 0 V 24 V Supply connections IP address for setting the IP address Functional earth LED Power MS NS L A 1 L A 2 EtherNet IPTM is registere...

Страница 9: ...of safety circuits and are designed for use in E STOP equipment Safety circuits in accordance with VDE 0113 Part 1 and EN 60204 1 The expansion module may not be used for safety related functions The...

Страница 10: ...ve a good knowledge of the generic and specialist standards applicable to the specific application 3 3 2 Warranty and liability All claims to warranty and liability will be rendered invalid if The pro...

Страница 11: ...onfigurator s online help INFORMATION The ESD file is available on the Internet at www pilz de 4 2 Data exchange 17 or 32 bytes must always be sent and received for communication with the PNOZmulti Fi...

Страница 12: ...yte 1 Bit 0 7 Byte 2 Bit 0 7 Byte 15 Bit 0 7 Status of LEDs LED status 1 Output Byte The LED status of the base unit can be requested directly as follows Bit 0 1 LED OFAULT is lit or flashes Bit 1 1 L...

Страница 13: ...Function description Operating Manual PNOZ m ES EtherNet IP 1003387 EN 05 13 4 4 Block diagram Interface to next module Data ST Ethernet IP Interface to previous module 24 V 0 V Module Supply...

Страница 14: ...equirements the mounting rail must have a low impedance con nection to the control cabinet housing The ambient temperature of the PNOZmulti units in the control cabinet must not exceed the figure stat...

Страница 15: ...modules is defined in the PNOZmulti Configurator The ex pansion modules are connected to the left or right of the base unit depending on the type Please refer to the document PNOZmulti System Expansio...

Страница 16: ...ard min Category 5 Measures to protect against interference Ensure the requirements for the industrial use of EtherNet IP are met as stated in the Installation Manual published by the User Group Exter...

Страница 17: ...or the commissioning and after every user program change you must check whether the safety devices are functioning correctly 6 5 Set IP address When setting the IP address please note Switch off the s...

Страница 18: ...om the DHCP Server when the DIP switch is set to 0 The module waits to receive an address from a DHCP Server If a fixed IP address was set previously and you wish to activate DHCP via DIP switch set t...

Страница 19: ...Commissioning Operating Manual PNOZ m ES EtherNet IP 1003387 EN 05 19 6 6 Connection example Ethernet IP Master Ethernet IP Slave 3 Ethernet IP Slave 2 Ethernet IP Slave 1...

Страница 20: ...not present L A1 green Bus connection present at X1 100 Mbit s green Data traffic present at X1 100 Mbit s orange Bus connection present at X1 10 Mbit s orange Data traffic present at X1 10 Mbit s Bus...

Страница 21: ...d for use with Internet Explorer or Firefox Make sure that Javascript and Cookies are enabled in your browser s security settings 7 2 1 Password administration Two users are preset for access to the w...

Страница 22: ...OZ m ES EtherNet IP to the PC 2 Call up the HTML page http 192 168 1 xxx For xxx enter the value that you have set as the last byte of the IP address 3 Enter the user name and password correctly and l...

Страница 23: ...mA Power consumption 0 2 W Max power dissipation of module 1 5 W Status indicator LED Fieldbus interface Fieldbus interface EtherNet IP Device type Adapter Transmission rates 10 MBit s 100 MBit s Con...

Страница 24: ...eldbus and module voltage Type of potential isolation Functional insulation Rated surge voltage 500 V Mechanical data Mounting position horizontally on mounting rail DIN rail Top hat rail 35 x 7 5 EN...

Страница 25: ...ails Operating Manual PNOZ m ES EtherNet IP 1003387 EN 05 25 Mechanical data Dimensions Height 101 4 mm Width 22 5 mm Depth 110 4 mm Weight 90 g Where standards are undated the 2014 04 latest editions...

Страница 26: ...eatures Order no PNOZ mm0 xp connector left Jumper yellow black to connect the modules 10 piece 779 260 Connection terminals Product type Features Order no Spring terminals PNOZ mmcxp 1 pc Spring load...

Страница 27: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Отзывы: