Wiring
Operating Manual PMCprotego S12(C)
1002528EN03
63
6.5.2
Singlepole outputs
Connector X30
Pin
Name
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
X30
5
STO Acknowledge
Status: STO activated
6
O0
Status: Safety function activated
7
O1
Status: Safety function activated
8
O2
Status: Safety function activated
9
O3
Status: Safety function activated
10
24 V Supply
Supply voltage for digital outputs
(24 V)
16
Ready
Status: Safety card ready for oper
ation and second output for feed
back from safety function STO
19
STO SIL3
Second STO shutdown route for
SIL 3
21
0 V Supply
Supply voltage for digital outputs
(0 V)
Connector pin assignment
Output circuit
Digital output
DI 5
6
7
8
X30
DI 4
5
DI 2
DI 1
DI 3
16
STO Acknowledge
O0
O1
O2
Ready
9
O3
0V
I/O-GND
21, 22
Shield
Servo Amplifier
DI 6
Shield
Shielded cable
Max. cable length: 30 m
24 VDC
Referenced to earth: 0V
Supply X30 Pin 21,22
Connection
Output circuit
Digital output
X30
19
STO SIL3
*)
Servo Amplifier
STO2-ENABLE
XGND
0V
**)
21
24 VDC
Referenced to earth: 0V
Supply
Connection