Function description
Operating Manual PMCprotego S12(C)
1002528EN03
18
– Current is supplied to the load
– Safety function activated
Supply voltage
}
24 VDC connection to supply the safety card's digital outputs
4.2.2.2
Dualpole outputs
The safety card has a safe dualpole output to control a mechanical brake:
}
SBC+/SBC
Signals at the output
}
“0” signal (0 V) at the output (SBC+/SBC):
– Output is high impedance
– No current to the load
– Safety function is activated, brake closed
}
“1” signal (+24 V) at the output (SBC+/SBC):
– Output is low impedance
– Current is supplied to the load
– Safety function is not activated, brake open
NOTICE
Only a brake which operates in accordance with the failsafe principle may
be connected.
Supply voltage
}
24 VDC connection to supply the safety card's digital outputs
4.2.2.3
Output test
The outputs are tested regularly:
}
Outputs that are switched on are checked via regular off tests.
– Test pulses for outputs that are switched on: see technical details
– Outputs that are switched on are switched off for the duration of the test pulse.
– The load must not switch off because of the test.
}
Outputs that are switched off are checked via regular on tests.
– Test pulses for outputs that are switched off: see technical details
– Outputs that are switched off are switched on for the duration of the test pulse.
– The load must not switch on because of the test.
Testing for shorts
}
A test is regularly carried out to check for shorts between the outputs.