Operation
Operating Manual PMCprimo MC
1003813-EN-03
| 57
Status of LEDs:
}
The "STAT" and "FUNC" LEDs light up green.
8.1.2.5
"STOP" operating status
In "STOP" operating status
}
No user program is run.
}
The system is operating without error.
}
It is possible to communicate with the motion controller in the terminal program via the
command language.
Status of LEDs:
}
"STAT" LED: Lights up green
}
"FUNC" LED: Off
8.1.2.6
"Fatal Error" operating status
"Fatal Error" operating status is reached when an error occurs.
}
The function is disrupted long-term The operating status is adopted temporarily.
}
The motion controller automatically changes back to "Startup" operating status.
}
The error is entered in the error stack.
Status of LEDs:
}
The "STAT" and "FUNC" LEDs light up red.
8.1.3
Change in operating status
-->
0
All operating states change to "Power Off"
The system changes to "Power Off" operating status when the 24 VDC supply voltage has
been switched off.
0
-->
1
Change from "Power Off" to "Startup"
The system changes to "Startup" operating status when the 24 VDC supply voltage has
been switched on.
1
-->
2
Change from "Startup" to "Boot Menu"
The "STAT" LED flashes green for 4 s, if the "Startup" operating status has been run
without error.
}
Press the reset button during this time to change to "Boot Menu" operating status.
1
-->
3
Change from "Startup" to "RUN"
"Startup" operating status has been run without error. The system changes to "RUN" status
if a user program was loaded in "Startup" status.
1
-->
4
Change from "Startup" to "STOP"