PIT gb
Operating Manual PIT gb
1004627-EN-02
13
Coloured caps
}
The control elements can be marked with coloured caps according to the function of the
control elements (see
Order reference: Accessories [
25]
)
Wiring
Please note:
}
Information given in the
Technical details [
21]
must be followed.
}
The power supply must meet the regulations for extra low voltages with protective sep-
aration (SELV, PELV) in accordance with EN 60204-1.
}
Ensure the wiring and EMC requirements of EN 60204-1 are met.
}
To connect the PIT gb to the evaluation devices, use a 12-pin cable with an A-coded
M12 female connector (see
Order reference: Accessories [
26]
).
Terminal assignment connectors
1
2
3
4
5
6
7
8
9
10
11
12
12-pin M12 male connector
PIN
Wire colour
1
Brown
2
Blue
3
White
4
Green
5
Pink
6
Yellow
7
Black
8
Grey
9
Red
10
Purple
11
Grey-pink
12
Red-blue
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory