PZE X5
Operating Manual PZE X5
1003301EN05
11
Times
774595
Switchon delay
With automatic start typ.
15 ms
With automatic start max.
30 ms
With automatic start after power on typ.
15 ms
With automatic start after power on max.
30 ms
Delayon deenergisation
With ESTOP typ.
13 ms
With ESTOP max.
30 ms
With power failure typ.
110 ms
With power failure max.
150 ms
Supply interruption before deenergisation in the input
circuit
8,0 ms
Supply interruption before deenergisation
20 ms
Environmental data
774595
Climatic suitability
EN 60068278
Ambient temperature
Temperature range
10 55 °C
Storage temperature
Temperature range
40 85 °C
Condensation during operation
Not permitted
EMC
EN 6094751, EN 6100062
Vibration
In accordance with the standard
EN 6006826
Frequency
10,0 55,0 Hz
Amplitude
0,35 mm
Airgap creepage
In accordance with the standard
EN 609471
Overvoltage category
III / II
Pollution degree
2
Rated insulation voltage
250 V
Rated impulse withstand voltage
4,00 kV
Protection type
Mounting area (e.g. control cabinet)
IP54
Housing
IP40
Terminals
IP20
Mechanical data
774595
Mounting position
Any
Mechanical life
10,000,000 cycles
Material
Bottom
PPO UL 94 V0
Front
ABS UL 94 V0
Top
PPO UL 94 V0