Regular checks and maintenance
Checks
Regular checks can bring to light changes to the plant/machine, safeguards and ambient
conditions.
Regular check
Pilz recommends that the safety light curtain be checked every six months.
}
Check the safety light curtain’s front panel.
– Scratched front panel: Replace the safety light curtain.
In a particularly dirty environment, front panel cleanliness should be checked more
frequently.
}
Check the tightness of the safety light curtain’s front panel.
All screws must be tightened to the torque specified in the
.
}
Check the safety function of the safety light curtain (see
Check the safety function of the
Checking of safety light curtains with beam coding
When switching on the safety light curtains, the correct function of the coding must be
checked.
INFORMATION
This inspection may only be carried out by qualified personnel.
The following LEDs must light after switching on:
Receiver
Status
Ready for operation
green
green
The current reception quality status