PSEN opII3H Series
Operating Manual PSEN opII3H Series
1003503-EN-05
| 35
5
3
1
2
4
5
3
1
0 V
24 V
0 V
OSSD 1
OSSD 2
0 V
24 V
24 V
24 V
24 V
T
x
R
x
uncoded
uncoded
uncoded
uncoded
PSENopII
receiver
PSENopII
transmitter
Evaluation device
Input circuit
External
supply voltage
Fig.: Dual-channel connection of an uncoded safety light curtain at the input circuit of an evaluation device
CAUTION!
Extension of the response time of the safety light curtain when using
the beam coding
When calculating the safety distance, remember the extended response
) with beam coding.
Changing from uncoded to coded operation is a change of the safety light
curtain and it requires a new risk assessment and hazard analysis.
– Perform a new risk assessment and hazard analysis and determine
the new
to the hazardous area with the
extended response time.