For your safety
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If spare actuators are used, these must be installed as described in
.
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
}
Do not remove the connector's protective cap until you are just about to connect the
unit. This will prevent potential contamination.
Unit features
}
The actuator PSEN 2.2-20 belongs to the safety switch.
}
Coded actuator
}
Safety switch with 4-pin M8 male connector
}
2 safety contacts (reed contacts - N/C and N/O)
}
Design: round (M30)
}
Operation Magnetic
}
Switching voltage 24 VDC
}
Series connection via PSEN i1 interface
}
ECOLAB tested
Function description
If the actuator is within the response range (safety gate closed), the safety contacts on the
safety switch will be switched. The N/O contact is closed and the N/C contact is opened.
The safety switch is designed for applications in series connections.
Operate the PSEN 2.2p-20 in conjunction with the following components:
}
Actuator PSEN 2.2-20 (see
}
) and
}
a connected evaluation device (see
Requirements and connection to evaluation
devices [