Intended use
The module may be used for failsafe applications in system environment B (automation
system PSS 4000).
}
The module monitors safety functions in accordance with EN 61800-5-2 for safe motion
monitoring.
The module performs the following monitoring functions:
–
Safe Speed Monitoring (SSM)
–
Safe Speed Range Monitoring (SSR-M)
–
Safe Operating Stop Monitoring (SOS-M)
–
Safe Direction Monitoring (SDI-M)
In accordance with EN ISO 13849-1 up to PL e and EN IEC 62061 up to SIL CL 3.
The module may only be used to monitor safety functions when the following blocks
are used:
–
FS_EI_Basic
–
FS_EI_SSM0
–
FS_EI_SOSM
–
FS_EI_SDIM
–
FS_EI_SSM1_SSRM
}
In the "FS_I_EI_CV" data type, the module provides a safe position counter value in ac-
cordance with EN ISO 13849-1 up to PL d and EN IEC 62061 up to SIL CL 2.
The modules PSSu K F EI CV and PSSu K F EI CV-T may be used as a safety compon-
ents in accordance with the Lifts Directive 95/16/EC in accordance with the requirements of
EN 81-1/2:1998+A3:2009, EN 81-20:2015, EN 81-50:2015, EN 81-22:2014 and
EN 115-1:2008+A1:2010.
The programmable safety system should be installed in a protected environment that meets
at least the requirements of pollution degree 2. Example: Protected inside space or control
cabinet with protection class IP54 and corresponding air conditioning.
Intended use includes making the electrical installation EMC-compliant. Please refer to the
guidelines stated in the "PSSuniversal Installation Manual". The module is designed for use
in an industrial environment. It is not suitable for use in a domestic environment, as this can
lead to interference.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the module
}
Use of the module outside the areas described in this manual
}
Any use of the module that is not in accordance with the technical details.