4. Charger installation
ź
Charger should be securely mounted on a flat surface
.
ź
It is recommended to mount
the
charger vertically for stationary applications and
horizontally for mobile applications.
ź
There should be enough space for airflow to and from the cooling openings.
ź
The charger should preferably be mounted in a dry compartment away from the
batteries.
ź
Note that batteries under charge must be properly ventilated. A light mixture of
hydrogen and oxygen can cause an explosion.
ź
Do not drill any holes on the housing!
5.
Protection functions
ź
Mains fuse in both lines (not user replaceable)
ź
Output fuse (not user replaceable)
ź
Overload and short-circuit protection
ź
High temperature protection with output power derating
ź
Overvoltage shutdown
ź
Undervoltage shutdown
ź
Non-sparking feature for safe battery connection
ź
Maximum charge time limit (TIMEOUT)
3. Technical specification
Input voltage
230V 15% 45-65Hz
±
Peak input current
Max 14A (limited)
Power factor
>0,99 at 50% load or more
Voltage model
110
220
360
Min output voltage
70V
150V
250V
Max output voltage
122V
250V
360V
Nominal output current
25A
16A
10A
Efficiency
>95% at 50% load or more
Output power
Max 3000W
Operating temperature
-40 to 60
°
C
Dimensions (L x W x H)
4
10 x 145 x 150mm
Weight
6,5kg (slave) - 6,9kg (master)
IP enclosure rating
IP21
Applicable Standards
IEC 61851-1, UL 2202 Compliant to IEC/UL 60950
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3
EN 61000-6-4, EN 61000-3-2
ENGLISH