8. Notifications
9. Warnings
COOLING FAN
vented models
only
Do not cover the cooling fan openings in order to ensure enough cooling flow. Ensure a
minimum of 30mm clearance at each end of the charger. Otherwise the charging
current will drop and the charging time will increase proportionally.
BATTERY
TYPE
Use the charger for the defined battery type only (according to the parameters). If the
charging profile does not suit the battery type, the battery will not be charged properly
and the life time of the battery may be shortened and in extreme case it may explode.
GAS
Lead-acid batteries produce hydrogen-oxygen gases which can be explosive. Make
sure that the working area is well-ventilated. Cigarettes or any open fires or sparks
may cause an explosion. Keep all ignition sources away from the battery.
ACID
Battery acid or other ingredients can damage your eyes and skin. In the event of an
accident, flush with water and seek medical help immediately. Use proper personal
protective devices when handling a damaged or leaking battery. Treat the material
used to clean up the battery acid spill as hazardous waste.
TOXIC
SUBSTANCES
Batteries contain hazardous materials. Among others, lead, antimony and cadmium
are toxic substances. All batteries are hazardous waste and must be treated
according to the Battery Disposal Regulations.
Notification
Description
INITIALIZING
Charger initialization procedure.
STARTING
Startup and self check.
READY
Charger ready for charging.
CHARGING
Charging the battery.
END
Charging completed. Battery full.
END (TIME-OUT)
Charging completed due to time limit.
BATT. VOLTAGE LOW
Battery voltage under the minimal value.
NO CHARGERS
No chargers detected.
WRONG CHARGER TYPE
Wrong charger voltage type detected.
ENGLISH