9
5
Set the All Red time:
Ensure that the
ALL RED
indicator is on.
If it is not, press the
MAX GRN
ALL RED
button located in the centre of the panel.
Using the measurement taken earlier
(from this phase’s
WAIT HERE
sign to
the
WAIT HERE
sign furthest away) and
the table shown below, repeatedly
press the phase timing button until the
appropriate time is shown on the 3-digit
readout.
Note: On steep gradients, increase the
ALL RED
time by 5 seconds for the uphill phase(s).
6
Set the Maximum Green time
Ensure that the
MAX GRN
indicator is on.
If it is not, press the
MAX GRN
ALL RED
button located in the centre of the panel.
...Setting the master (cont.) - Vehicle phases
For each vehicle phase that you need to use:
4
Repeatedly press
MODE/DEMAND
for the phase
until the required setting is illuminated:
selects one approach, one head
per approach,
selects one approach, two heads
per approach,
selects two approaches,
one head per approach (aka: two
opposed heads).
Note: When the
option is lit, a further press
of
MODE/DEMAND
will switch off that phase.
0m
5
seconds
10
seconds
15
seconds
20
seconds
25
seconds
30
seconds
50m
100m
150m
200m
250m
300m
0m
35
seconds
40
seconds
45
seconds
50
seconds
75m
135m
195m
300m
7
If this and the neighbouring phase need to be linked in order
to provide more heads per approach, see page 12 for details.
Using the measurement taken earlier
(from this phase’s
WAIT HERE
sign to the
WAIT HERE
sign furthest away) and the
table shown below, repeatedly press the
button until the appropriate time is shown
on the 3-digit readout.
8
Repeat steps
4
to
7
for each active phase and then:
Next