❖ Water must be clean and the Chlorine cont should be less than 100mg/L.
❖ Don't add corrosive water into coffee machine.
❖ Carbonate hardness must be less than 5-6
°
dKH(German carbonate
hardness) or 8.9 -10.7
°
fKH (French carbonate hardness), and to
tal hardness must be always higher than the carbonate hardness.
❖ Minimum carbonate hardness between 5
°
dKH or 8.9
°
fKH. PH sho
uld between 6.5 -7.
❖ Only use a new tube set! It is not permitted to connect old or used
tube sets.
• Water connection under the instructions and the local regulations. If
the machine is connected with a new tube, then make sure the tube is
clean.
• The machine must be connected into the tube which with shut-off tap.
Install the machine on the water tape pressure reducer through pressure
tube and screw connection G 3/8'.(Adjust it to 0.3 MPa (3 bar)).
5. 2 Installation
5. 2. 1
Coffee Machine
• Open the carton box, take out machine and spare parts. The machine
and all accessory units are only permitted to be installed and stored in
frost-free locations.
• Take out machine and accessories, install the cooler at the right side
of coffee machine.
✓ Machine installation.
16
Содержание K95
Страница 1: ...Pierro K95 Version 2 Please read the instructions carefully and keep it well ...
Страница 47: ...Step 2 Clink Service Menu tab to the next step Step 3 Input password 1609 tab to the service menu 46 ...
Страница 48: ...Step 4 Click Maintenance then Water draining tab to the next step Step 5 Click OK tab to the next step 47 ...
Страница 59: ... Don t use machine when the tape water is stopped If the machine s upplied with tape water 58 ...
Страница 60: ......