Picote Solutions Oy Ltd
38
www.picoteinstitute.com
STEP 1
STEP 3
STEP 2
When you have finished coating, turn the pump rotation to
reverse
. This will pull the
resin back to the cup and reduce resin dripping during the cleaning process. When the
resin stops dripping, put the brushes in a bucket of acetone. Cover the opening and run
brushes for a short time to rinse off resin. Brushes and cable should now be clean
enough to reuse later.
Wipe the camera head and the Miller shaft clean with an acetone soaked rag.
Cut away tape then recoil the cleaned camera and miller cables into their holders.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
CLEANING UP THE COATING SYSTEM cont.