Picote Solutions Oy Ltd
33
www.picoteinstitute.com
After priming the static mixing tip, allow the resin to begin filling the resin cup to no more than ⅓ full.
Filling the cup too full will generate heat too quickly and reduce the overall working time.
STEP 1
Once the cup is 1/3 full, begin priming the delivery hose. Set the variable speed dial on
the pump to full speed and engage the pump to begin priming the delivery hose.
If the piping system has several bends that are difficult to
navigate or if the line set is difficult to push through the
pipe, a special lubricant can be used to reduce friction. The
Picote Delivery Hose Lube should added to a spray bottle to
be easily applied to the outside of the line set. Lightly coat
the line set as it is being pushed into the pipe.
Please note:
The lubricant is highly specialised and designed
to be absorbed into the coating resin without causing any
negative effects. Any other lubricant WILL cause negative
effects and can prevent the epoxy from bonding or curing
properly. Excessive use is not needed nor recommended.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
OPERATING THE COATING SYSTEM cont.
32
TIP