Rev. 01/2021
17
Trigger Modes
The driver can be configured by the user for internal, external or cw trigger.
CW
When the cw mode is configured the LDP-C behaves like the LDP-CW series. See above for
more details.
External
The output stage is controlled by the PULSE signal. Like the cw mode, the current regulator
is controlled by the ENABLE signal and L_ON bit, but the output stage is controlled
separately. Hence, the user can enable the internal current flow, but wait for the soft start to
be finished before enabling the output stage. This will lead to a very low rise time compared
to the soft start. The actual rise time can be configured using the digital control.
Please see sections “Soft Start” and “Timing Diagram” for more details.
Internal
The output stage is controlled by an internal pulse generator which can be enabled / disabled
using the L_ON bit in the LSTAT register. The PULS input is not used. The values for pulse
width and repetition rate can be configured via USB or the PLB-21.
Please see sections “Soft Start” and “Timing Diagram” for more details.