Description of the ERROR Register
The following list contains a description of the individual bits of the ERROR register. A “1”
as a bit leads to a deactivation of the drivers output. Bit 11 is excluded of this directive as it is
just a warning.
Bit
Name
Read/Write Meaning
0
CRC_DEVDRV
Read
Indicates a CRC error in the PLB-
Driver. It does not affect the driver,
but might disable the PLB-21 usage.
1
CRC_DEFAULT
Read
Indicates a CRC error in the stored
default values. The values should be
re-saved
2
CRC_CONFIG
Read
Indicates a CRC error in the
configuration. The driver must be
repaired
3
CRC_PARAM
Read
Reserved
4
CRC_CAL
Read
Indicates a CRC error in the
calibration. The driver must be
repaired
5
VCC_LOW
Read
Indicates that the Supply voltage is
too low
6
VCC_HIGH
Read
Indicates that the Supply voltage is
too high
7
VCC_UVLO
Read
Indicates that the Supply voltage
has dropped during operation.
Check the current limitation of the
power supply.
8
FAILED_DEFAULT
Read
The default values could not be
loaded during power-on.
9
TEMP_OVERSTEPPED
Read
The operation temperature has
exceeded 80°C
10
TEMP_HYSTERESE
Read
The driver needs to cool down
11
TEMP_WARNING
Read
The drivers operation temperature
reaches critical levels
12
ENABLE_POWERON
Read
Enable was given during power-on
13
ENABLE_ENCHANGE
Read
Enable was given while switching
between internal / external
14
PWM_MAX
Read
The current regulator was unable to
generate the desired output current