5 Installation
30
Version: 1.0.0
PZ265E
PL0xx/PDxxx Piezo Actuator
If the PL0xx/PDxxx is not short-circuited: The PL0xx/PDxxx is discharged (p. 40).
The electronics are
switched off
.
The electronics have a single-pole LEMO socket.
Models without stranded wires: You have soldered (p. 22) or glued (p. 24) a red
stranded wire to the positive electrode (+) and a black stranded wire to the negative
electrode (-) of the PL0xx/PDxxx.
Tools and accessories
P-890.xx coaxial cable (p. 12), LEMO single-pole to open end (can be ordered
separately)
Suitable soldering iron
Suitable solder
Suitable cable tools
Connecting the PL0xx/PDxxx to the electronics
1.
If necessary, shorten the wire and the cable shield of the coaxial cable to the correct
length.
2.
Make the stranded wires of the PL0xx/PDxxx accessible:
−
When the stranded wires of the PL0xx/PDxxx are short-circuited, disconnect the
connection between the stranded wires.
−
Remove all aids and components that have been connected to the PL0xx/PDxxx for
short-circuiting or discharging (e.g., conductive rubber or discharging resistor).
3.
Solder the red stranded wire of the PL0xx/PDxxx to the wire of the coaxial cable that is
connected to the inner contact of the LEMO connector.
4.
Solder the black stranded wire of the PL0xx/PDxxx to the cable shield of the coaxial
cable.
5.
Insulate the soldered cable connections in a suitable manner.
6.
Connect the connector of the PL0xx/PDxxx to the corresponding connection on the
electronics.