5 Installation
N565 NEXACT® Linear Stage
MP148E
Version: 1.4.0
21
Fixing the load to the N565
Figure 8: Mounting holes for fixing the load to the platform
1
8 × M2.5 holes with 4 mm thread depth
2
18 × M2 holes with 3 mm thread depth
3
4 × M3 holes with 5 mm thread depth
Refer to Dimensions (p. 36) for the exact position
1.
Align the load so that the selected mounting holes in the platform can be used to fix it.
2.
Use the screws to fix the load to the selected mounting holes in the platform.
Maximum screw-in depth in the platform of the N-565:
−
M2 screws: 3 mm
−
M2.5 screws: 4 mm
−
M3 screws: 5 mm
Maximum torque:
−
M2 screws: 0.3 Nm
−
M2.5 screws: 0.7 Nm
−
M3 screws: 1.3 Nm
3.
Check that the load is sitting firmly on the platform of the positioner.