8 Troubleshooting
N472 Linear Actuator
MP144E
Version: 1.3.0
33
Problem
Possible causes
Solution
No or limited
motion
The cable is not
connected correctly
or is defective
Check the connecting cables.
Excessive
counterforces in
the direction of
motion
Reduce the load. Pay attention to the
information in the "Technical Data" section
(p. 37).
Parameters of the
controller
incorrectly set
Load the parameter set from the positioner
database that corresponds to the N-472
model.
If necessary: In the PIMikroMove PC
program, set the parameters of the
controller so that they correspond to the
application (load, orientation) of the N-472
model (see user manual for the controller).
Motor/drive is
blocked
Loosen the fine-threaded screw by turning
the screw head backwards and forwards by
hand.
If the problem that occurred with your system is not listed in the table above or cannot be
solved as described, contact our customer service department (p. 35).