Unit
Toler-
ance
L-505.02A212F
Recommended controllers/drivers
C-663.12 (single axis)
SMC Hydra (double axis)
C-885 with C-663.12C885 (up
to 20 axes)
ACS modular controller
Operating temperature range
°C
5 to 40
12.2
Maximum Ratings
The L-505.02A212F is designed for the following operating data:
Maximum operating voltage Maximum Operating Fre-
quency
Maximum power consump-
tion
48 V
‑
2 W
12.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the L-505.02A212F must be
observed:
Area of application
For indoor use only
Maximum altitude
2000 m above msl
Relative humidity
20 to 80%, not condensing
Storage temperature
-20 °C to +70 °C
Transport temperature
-20 °C to +70 °C
Supply voltage fluctuations
Max. ±10 % of the nominal voltage
Degree of pollution
2
Degree of protection according to IEC 60529 IP00
12 TECHNICAL DATA
L505M0020EN
‒
10/22/2018
33