![PI L-505.02A212F Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/pi/l-505-02a212f/l-505-02a212f_user-manual_1554409021.webp)
✓
You have prepared the load so that it can be affixed to the mounting holes on the motion
platform:
■
The distance between the center of gravity of the load and the center of the motion
platform is as small as possible in all directions.
■
At least three points are provided for affixing the load on the motion platform.
NOTICE
Impermissibly high load on the L-505.02A212F
An impermissibly high load impairs the motion of the motion platform and can damage the
L-505.02A212F.
►
Pay attention to the
maximum permissible forces (p. 31)
that may act on the motion
platform.
►
In the case of multi-axis systems, include the masses of the positioners to be moved
when calculating the load.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the L-505.02A212F.
►
Pay attention to the
depth of the mounting and locating holes (p. 34)
.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
Affixing the Load
1. If necessary: Insert the locating pins into the corresponding holes in the motion platform.
2. Align the load on the motion platform so that the mounting holes selected in the motion
platform can be used for mounting the load.
3. Place the load onto the motion platform so that the locating pins are inserted into the
corresponding locating holes in the load.
4. Tighten the screws in all mounting holes.
5. Check that the load is affixed firmly to the motion platform.
6.6
Connecting the L-505.02A212F
Tools and Accessories
■
Wenn nötig: Suitable cable set
■
If necessary: Suitable screwdriver for the locking screws of the connectors.
Requirements
✓
You have read and understood the
general safety instructions (p. 8)
.
✓
You have read and understood the user manual for the electronics used.
✓
You have installed the electronics properly.
✓
The electronics are switched off.
NOTICE
Damage due to incorrect connection of the L-505.02A212F!
Connecting unsuitable electronics or a wrong cable can damage the L-505.02A212F or the
electronics.
►
Connect the L-505.02A212F to
suitable electronics (p. 11)
from PI miCos only.
►
Use cables from PI miCos only to connect the L-505.02A212F to the electronics.
6 INSTALLATION
L505M0020EN
‒
10/22/2018
21