phytron
25
MA 1273-A007 EN
6.2 Electrical Installation
Ensure sufficient bending radius of the cables during installation. Do not lay the cables in
tension or bend them.
We recommend labelling the mating connectors to prevent interchanging the connectors.
If all the connections are made, the last step is to plug in the power supply to the mains.
6.2.1 Connectors – Overview
Module
type
Connector Number
of pins
Connector
on the
module
(Phoenix)
Mating connector
(Phoenix)
Mating
connector ID
number
POWM01
and
POWM02
+(24…70) V
Supply
1x2 PC4/2-G-7,62
PC4/22-ST-7,62
10014443
+24 V
Supply
1x2 MCDN1,5/2-
G1-3,5P26
FMC1,5/2-ST-3,5 10007077
POWM03
and
POWM04
+24 V OUT
1x2 MCDN1,5/2-
G1-3,5P26
FMC1,5/2-ST-3,5 10007077
The mating connector is included in delivery of the module and is usually plugged into the
module at the factory.
i
CAUTION – Possible error messages!
The POWM module generates from the 24 V
DC
I/O supply voltage the
internal supply voltage of the SUB modules (i.e. limit or reference switches)
and of the DIOM module.
- Please ensure that the24 V
DC
I/O supply voltage is always connected.