5.5 Features POWM02 and POWM04
If the total current of all modules in a voltage group (20 A) is exceeded, or if a voltage
group has various voltages to begin with, the POWM02 and POWM04 module must be
applied for the supply of the power stages and I/Os.
A power module can be inserted only in designated slots. These slots must be already
defined before ordering the
phy
MOTION
TM
.
Features
Power supply
POWM02
EXT
24…70 V
DC
/ max.20 A (motor supply U
B
)
+24
V
DC
(
±20%)
electrically isolated / max. 5 A (I/O supply)
POWM04
INT
48 / 70 V
DC
/ max.20 A (motor supply U
B
)
+24
V
DC
(
±20%)
electrically isolated / max. 5 A (I/O supply)
+24
V
DC
output voltage i.e. for sensors
Voltage range
POWM02
between 24…70 V
DC
and 24 V
DC
I/O
POWM04
between 48 / 70 V
DC
and 24 V
DC
I/O
Current capacity
max. 20 A / U
B
, max. 5 A / +24 V
DC
The total current at + 24V
DC
for all inputs / outputs, as well as
limit and reference switches, encoders and sensors incl. the
24 V
DC
tap of POWM03 / 04 modules must not exceed the
value of 5 A per total
phy
MOTION
TM
.
Power loss
POWM02 / POWM04
1400 mW at U
B
= 70 V
Over voltage protection
no
Short circuit protection
Logic voltage (5 V): auto-reset 2.6 A
U
B
: 2 x 10 A
Diagnostics
2 status LEDs on the front panel
Содержание phyMOTION POWM01.2
Страница 11: ...phytron 11 MA 1273 A007 EN 5 Technical Data 5 1 Declaration of Incorporation Modules gen and ext Supply EXT...
Страница 12: ...Manual POWM01 POWM02 POWM03 POWM04 MA 1273 A007 EN 12...
Страница 13: ...phytron 13 MA 1273 A007 EN 5 2 Declaration of Incorporation Modules with internal Supply INT...
Страница 14: ...Manual POWM01 POWM02 POWM03 POWM04 MA 1273 A007 EN 14...