Manual POWM01 / POWM02 / POWM03 / POWM04
MA 1273-A007 EN
20
4.5 Functions
POWM01 and POWM02:
Feed-in to the power supply:
•
24 to 70 V
DC
supply voltage (for motors and generates internally the logic
voltages) – 20 A max.
•
Optional electrically isolated 24 V
DC
for inputs/outputs, limit and reference switches
POWM03 and POWM04:
Feed-in to the power supply:
•
48 and 70 V
DC
supply voltage (for motors and generates internally the logic
voltages) – 20 A max.
•
Optional electrically isolated 24 V
DC
for inputs/outputs, limit and reference switches
•
+24
V
DC
output voltages i.e. for sensors
The total current at + 24V
DC
for all inputs / outputs, as well as limit and reference
switches, encoders and sensors incl. the 24 V
DC
tap of POWM03 / 04 modules must
not exceed the value of 5 A per total
phy
MOTION
TM
..
Only POWM01 and POWM03:
Configuration:
•
USB
interface for programming and diagnostics
•
Device address switch
for setting a fixed bus address
(is necessary e.g. with RS 485, CAN etc.)
•
Remote/Local switch
for switching the mode from
Remote
(controller receives the
commands via HOST interface) to
Local
(the controller is running in pure
stand-alone mode with a sequential program).
•
Reset button
for the resetting of the controller
•
Connection of an external phytron t
ouch panel
(e.g. Android-based tablet)
Содержание phyMOTION POWM01.2
Страница 11: ...phytron 11 MA 1273 A007 EN 5 Technical Data 5 1 Declaration of Incorporation Modules gen and ext Supply EXT...
Страница 12: ...Manual POWM01 POWM02 POWM03 POWM04 MA 1273 A007 EN 12...
Страница 13: ...phytron 13 MA 1273 A007 EN 5 2 Declaration of Incorporation Modules with internal Supply INT...
Страница 14: ...Manual POWM01 POWM02 POWM03 POWM04 MA 1273 A007 EN 14...