phytron
15
MA 1277-A011 EN
Before integrating or switching modules always make sure that the
phyMOTION
™ is shut
down and the power supplies are disconnected.
WARNING
– Serious injury from electric shock!
During electrical installation cables, connectors, etc. can be live.
- Before starting wiring, make sure that none of the power supplies
are connected to the primary side of the mains supply. Isolate the
power supplies from the mains or remove the appropriate fuses.
- All modules must be inserted and screwed into the
phyMOTION
TM
housing before powering up. If necessary, unoccupied module
slots must be covered with the supplied blank front plates.
Never operate the equipment when open.
- Do not plug or unplug the modules while powered.
- Do not plug or unplug the connectors while powered.
- If the equipment was energised, wait 3 minutes after power off to
allow the capacitors to discharge and ensure that there are no
residual charges on cables, connectors and boards.
Make sure not to leave free slots in between modules so the module addressing sequence
can work correctly.
Identify the correct slot position for your EXAM01 module referring to your order and
documentation
– the EXAM01 needs at least a preceding Indexer module (i.e. I4XM01), a
POWM01 or POWM02 and the MCM01 main controller module.
The EXAM01 module is always built as a sandwich with its subsequent indexer module
(i.e. I4XM01). Cut the red seal tape and the black label tape carefully on the left and right
edge of the module/front panel which you want to remove. Don’t slide the blade between
the front panels by no means.When backfitting by our service the red seal tape is
renewed.
Connect the EXAM01 module to the connector (2x13 pole, ribbon cable) with the
appropriate indexer modules from the rear side.
Push the sandwich module carefully into the guide rail until the rear contacts the housing
frame of the
phyMOTION
TM
.
In the last few
millimetres the module’s plug has to match with the backplane’s socket. You
should be able to push in the module with light pressure. In case you experience problems
move the module’s front plate slightly to the left and to the right while pushing in the
module, so that the plug’s pins can slide into the backplane’s socket.
As soon as the module’s front plate contacts the housing’s frame the module is integrated
properly and can be fixed with two electro-conductive bolts.
Now you can start with the electrical installation.