WARNING
– Serious injury from electric shock!
If the phyMOTION
TM
is not operated with SELV/PELV voltages, the risk of
dangerous voltages may be on the device. Touching these components
carrying high voltages can cause serious injury or death from electric shock:
- Always observe the safety concept SELV / PELV to ensure safe
isolation and separation of low voltage supplies from the mains.
WARNING
– Serious injury from electric shock!
During electrical installation cables, connectors, etc. can be live.
- Before starting wiring, make sure that none of the power supplies
are connected to the primary side of the mains supply. Isolate the
power supplies from the mains or remove the appropriate fuses.
- All modules must be inserted and screwed into the
phyMOTION
TM
housing before powering up. If necessary, unoccupied module
slots must be covered with the supplied blank front plates.
Never operate the equipment when open.
- Do not plug or unplug the modules while powered.
- Do not plug or unplug the connectors while powered.
- If the equipment was energised, wait 3 minutes after power off to allow
the capacitors to discharge and ensure that there are no residual
charges on cables, connectors and boards.