![phytron MCD+ Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/phytron/mcd/mcd_manual_1554199044.webp)
Manual MCD
+
MA 2102-A005 GB
42
Instruction
code
Parameter
name
Type Value
Description
De-
fault
values
W Write
EPROM
X –
Write
parameter into EPROM
–
Z
Motor test
X
+ or –
Self test: one motor rotation with
preset run current
–
9.2.1 Extra Parameters
Instruction
code
Parameter
name
Type Value
Description
De-
fault
values
PB Operation
mode
R/W 0 or 1
Set operation mode
0 = Bus
1 = Stand alone
1
PC Current
Shaping
R/W 0 or 1
Define Current Shaping CS
0 = On
1 = Off
0
PH Overdrive
upper
switching
frequency
R/W 225
to
225,000
Define Overdrive upper switching
frequency
unit: Hz
PN
Axis name
R/W <String
Assign or read an axis name
(max. 40 characters) into the
EPROM
–
PO
Overdrive
R/W 0 or 1
Define function Overdrive
0 = Off
1 = On
1
PX Bus
mode
eXclusive
R/W 0 or 1
Rotary switch
0= Don’t ignore rotary switches
1= Ignore rotary switches
0
Содержание MCD+
Страница 1: ...Manual 2102 A005 GB MCD Compact Stepper Motor Power Stage for Wall Mounting...
Страница 2: ......
Страница 3: ...phytron 03 2008 Manual MA 2102 A005 GB MCD 93 70 Compact Stepper Motor Power Stage for Wall Mounting...
Страница 26: ...Manual MCD 6 3 Wiring Schemes Fig 21 Connection diagrams for 4 6 and 8 wire stepper motors MA 2102 A005 GB 24...
Страница 55: ...phytron Appendix C Declarations of Conformity 53 MA 2102 A005 GB...
Страница 56: ...Manual MCD MA 2102 A005 GB 54...
Страница 59: ......