Manual MCD
+
2 Technical Data Table
Technical Data
Stepper motor
2-phase-stepper motors with 4, 6 or 8 lead wiring scheme
Winding resistance between 0.1 and 10 Ohm
Winding inductance 0.5 to 10 mH per phase
Step resolution
Rotary switch mode
The step resolution can be set by the rotary switch:
1/1, 1/2, 1/4, 1/5, 1/8, 1/10, 1/20 of a full step.
ServiceBus mode The step resolution is programmable:
1/1, 1/2, 1/4, 1/5, 1/8, 1/10, 1/16, 1/20, 1/32, 1/64, 1/128,
1/256, 1/512 of a full step.
Phase currents
Rotary switch mode
Run current and stop current can be individually set by the
rotary switches.
Run current and stop current can be changed between 2
ranges by the rotary switch CURRENT RANGE SETTING
(
I
and
II
).
Factory settings:
Rotary switch:
I
(= low range)
All rotary switches: ‚0’
Rotary switch position
Range I
Range II
Run and stop current
Run and stop current
0.2 to 1.6 A
r.m.s.
(without Boost) in 0.1 A steps
0.3 to 2.1 A
r.m.s.
(with Boost)
0.4 to 3 A
Peak
0.6 to 5 A
r.m.s.
(without Boost) in 0.3 A steps
0.8 to 6.3 A
r.m.s.
(with Boost)
1.1 to 9 A
Peak
ServiceBus mode Run and stop current can be set independently by program.
Programmable from 0.1 to 5 A
r.m.s.
in 100 mA steps
Lead cross section of
the motor cable
Minimum 1 mm² is recommended at max. current.
Supply voltage
Unregulated filtered DC voltage from 24 to 70 V
DC
Nominal voltage 70 VDC
Reinforced or double insulation between mains and
secondary circuit.
MA 2102-A005 GB
12
Содержание MCD+
Страница 1: ...Manual 2102 A005 GB MCD Compact Stepper Motor Power Stage for Wall Mounting...
Страница 2: ......
Страница 3: ...phytron 03 2008 Manual MA 2102 A005 GB MCD 93 70 Compact Stepper Motor Power Stage for Wall Mounting...
Страница 26: ...Manual MCD 6 3 Wiring Schemes Fig 21 Connection diagrams for 4 6 and 8 wire stepper motors MA 2102 A005 GB 24...
Страница 55: ...phytron Appendix C Declarations of Conformity 53 MA 2102 A005 GB...
Страница 56: ...Manual MCD MA 2102 A005 GB 54...
Страница 59: ......