Set up phase currents correctly fitting to the motor winding's design current!
•
The stop current is normally set to 40-50% of the run current, to keep the motor
temperature as low as possible.
•
The table values refer to current values, if both motor phases are activated. The
current in one phase is calculated as: table value x
2
•
Max. run /stop current in Rotary switch mode: range
I
: 1.6 A x
2
x 1.3 = 3 A
range
II
: 5 A x
2
x 1.3 = 9 A
•
Important:
The run and stop current values, which are set by the rotary switches,
depend on the selected current rage, that means
Run current
(without Boost)
Stop current
(without Boost)
Range
I
0.2 to 1.6 A
r.m.s.
0.2 to 1.6 A
r.m.s.
Range
II
0.6 to 5 A
r.m.s.
0.6 to 5 A
r.m.s.
The switch positions may be changed
•
while the MCD is powered off or
•
the power stage is deactivated. However, after changing the switch
position the power stage should be reset by the input Reset.
Short circuit
phase to phase and phase to ground
is
detected from a current
setting of 0.7 A
r.m.s.
!
33
MA 2102-A005 GB
Содержание MCD+
Страница 1: ...Manual 2102 A005 GB MCD Compact Stepper Motor Power Stage for Wall Mounting...
Страница 2: ......
Страница 3: ...phytron 03 2008 Manual MA 2102 A005 GB MCD 93 70 Compact Stepper Motor Power Stage for Wall Mounting...
Страница 26: ...Manual MCD 6 3 Wiring Schemes Fig 21 Connection diagrams for 4 6 and 8 wire stepper motors MA 2102 A005 GB 24...
Страница 55: ...phytron Appendix C Declarations of Conformity 53 MA 2102 A005 GB...
Страница 56: ...Manual MCD MA 2102 A005 GB 54...
Страница 59: ......