9 Bus Connection Configuration
If operating more than one MCD device (max. 16) at one serial interface, the RS485 field
bus is the best choice.
Many parameters in the MCD can be set by the serial bus connection. Thus, a safe
stepper motor operation with correct preset parameters is assured.
9.1 Definition
The bus connection is defined as follows:
•
RS485: 4 wire connection, also point to point connection possible
•
Signal input: R+ R-
•
Signal output: T+ T-
•
insulated from the motor voltage by means of optocoupler
A well-defined protocol should be followed to assure a safe data exchange:
Asynchronous transmission, 8 bits/byte, 1 stop bit, 1 parity bit
Transmission rate: 57600 Baud
Permanent telegram format:
<STX> <address_H><address_L> <instruction> <value> : <csh> <csl> < ETX>
<STX>
Start-of-text character, 02
H
<address_H> High-order
byte
of the power stage address 00
H
...0F
H
,
0
D
…15
D
;
Admissible characters: 0…F
<address_L> Low-order
byte
of the power stage address 00
H
...0F
H
,
0
D
…15
D
;
Admissible characters: 0…F
<instruction> Instruction
byte:
A....Z
<value> Data
byte
:
Colon as separator, to distinguish between usable data
and checksum
<csh>
Upper byte of the 8 bit checksum value
<csl>
lower byte of the 8 bit checksum value
< ETX>
End-of-text character, 03
H
Содержание MCD+
Страница 1: ...Manual 2102 A005 GB MCD Compact Stepper Motor Power Stage for Wall Mounting...
Страница 2: ......
Страница 3: ...phytron 03 2008 Manual MA 2102 A005 GB MCD 93 70 Compact Stepper Motor Power Stage for Wall Mounting...
Страница 26: ...Manual MCD 6 3 Wiring Schemes Fig 21 Connection diagrams for 4 6 and 8 wire stepper motors MA 2102 A005 GB 24...
Страница 55: ...phytron Appendix C Declarations of Conformity 53 MA 2102 A005 GB...
Страница 56: ...Manual MCD MA 2102 A005 GB 54...
Страница 59: ......