HOW TO DETERMINE VPD TARGETS 

MIST 

To determine the target for a particular station, do the following: In the SET 

STATION MODE for a MIST STATION, enter a large target. (our recommendation for 
early crop mist is 1000). The large target is to ensure the station won’t automatically water 
the crop until the grower has determined the daily target. When the grower believes the 
mist station needs to be watered, do the following: In the MANUAL MODE, choose the 
mist station and activate it while noting the time of day. When the plants need to be 
watered the very next time, 

(THE GROWER NEEDS TO DETERMINE THIS BY 

PHYSICALLY WATCHING THE PLANTS)

, note the reading of the Accumulated 

VPD for this station in the SHOW SYSTEM MODE as well as the new time of day. You 
now have the target for the day. Go into the SET STATION MODE, choose the station and 
enter in the new target. 
 

REMEMBER THE PLANTS NEED WATER! NOW THAT YOU’VE 
NOTED THE ACCUMULATED VPD AND THE TIME, GO BACK 
INTO THE MANUAL MODE AND ACTIVATE THE STATION SO 
THE PLANTS GET SOME WATER! 
 

To go the next step with the available information, the targets for each day that the crop 
will be under mist at this specific station can be calculated. Do the following: Take the 
NEW TARGET and divide by the number of minutes between the two mists. This gives 
the VPD per minute. For each daily target, calculate how much time between each misting 
for that specific day if the environmental conditions were identical to the first target. 
Multiply the number of minutes by the VPD per minute to develop a target for each day. 
Hint: If developing a model for mist to propagate young plants, the targets should go up as 
the plant grows. 

Targets going up mean that the amount of mist is going down.

 

 

IRRIGATION 

To determine the target for a particular station, do the following: In the 

SET STATION MODE for an IRRIGATION STATION, enter a large target (our 
recommendation for small plant irrigation is 10000). The large target is to ensure the 
station won’t automatically water the crop until the grower determines the daily target. 
When the grower believes the irrigation station needs to be watered, do the following: In 
the MANUAL MODE, choose the station and activate it while noting the time of day. 
When the plants are ready to be watered the very next time 

(THE GROWER NEEDS TO 

DETERMINE THIS BY PHYSICALLY WATCHING THE PLANTS)

, note the 

reading of the Accumulated VPD for this station in the SHOW SYSTEM MODE as well 
as the new time of day. You now have the target for the day. Go into the SET STATION 
MODE, choose the station and enter in the new target. 
 

REMEMBER THE PLANTS NEED WATER! NOW THAT YOU’VE 
NOTED THE ACCUMULATED VPD AND THE TIME, GO BACK 
INTO THE MANUAL MODE AND ACTIVATE THE STATION SO 
THE PLANTS GET SOME WATER! 
 

Содержание WATER PRO

Страница 1: ...13688 Rider Trl N Earth City MO 63045 PHONE 314 770 0717 FAX 314 506 4587 www phytotronics com Revision 1 2 10 15 2021 Water Pro VPD Misting and Irrigation Control...

Страница 2: ...er ELECTRICAL CIRCUIT The electrical circuit that feeds the machine tool transformer must have no other loads connected to it This will prevent damaging surges from other related electrical devices Fo...

Страница 3: ...from your solenoid valves 24VAC type to the WATER PRO EXPANSION module plugs 3 Make sure all plugs are secured into the WATER PRO EXPANSION module then turn the screw locking the panel in its enclosur...

Страница 4: ...vating the next Output Station FEATURES OF THE EQUIPMENT INPUTS and OUTPUTS The Sensor Inputs to the WATER PRO are as follows 1 Air Temperature 1 from VPD Sensor 1 2 Leaf Temperature 1 from VPD Sensor...

Страница 5: ...r Air Temperature 1 Leaf Temperature 1 Relative Humidity 1 Air Temperature 2 If optional sensor installed Leaf Temperature 2 If optional sensor installed Relative Humidity 2 If optional sensor install...

Страница 6: ...of time left on an active watering cycle Note Answer all questions with only the number of stations crop aging groups and disable groups that are currently being set up This will prevent the unit fro...

Страница 7: ...nrise When attaching the Disable Group to an irrigation station the irrigation station will disable for the amount of time called for in the Disable Group prior to Sunset No matter what type of statio...

Страница 8: ...wo mists This gives the VPD per minute For each daily target calculate how much time between each misting for that specific day if the environmental conditions were identical to the first target Multi...

Страница 9: ...lant must have water After watering the plant the process starts all over again Just what is VPD and how does it relate to plants To understand VPD we must understand the following 1 How water moves t...

Страница 10: ...he VPD accumulation The Set System Mode is where the accumulated VPD information is displayed as it approaches the target that was entered in the Set Station Mode When a station zone needs to be water...

Страница 11: ...be 2 When the timer or other device waters the plants go into the Manual Mode and Trigger the Station with the high fixed target To do this a Use the RUN SET switch to go into the Manual Mode b Use th...

Страница 12: ...get If attempting to determine a new target enter a high target 1000 for a misting station and 50 000 for an irrigation station Use the VALUE and the PRIOR NEXT switches to enter this target Refer to...

Страница 13: ...program or to Stop Watering Use the VALUE switch to enter this choice 36 Push the PRIOR NEXT switch to NEXT to go to the next question 37 Choose whether or not to use a DISABLE program Use the VALUE...

Страница 14: ...go to the next question 11 Choose the final day target If attempting to determine this target refer to the section How To Determine Correct Watering Targets 12 Push the PRIOR NEXT switch to NEXT to go...

Страница 15: ...sunrise 8 Push the PRIOR NEXT switch to NEXT to go to the next question WARNING If this is the FIRST TIME this crop age program has been set up choose Yes Reset First The WATER PRO resets the targets...

Страница 16: ...lations Only in the Manual Mode can the VPD Accumulation for a station be zeroed out NOTE USE OF THE ON OFF AUTO SWITCHES DO NOT ZERO OUT VPD ACCUMULATIONS Example 2 TRIG STATION 1 If the zone connect...

Страница 17: ...17...

Страница 18: ...only and sole liability of Phytotronics Inc under this warranty is limited to repairing replacing or the issuance of credit for any products returned to Phytotronics Inc during the warranty period of...

Отзывы: