6
NOTE: THIS IS THE ONLY MODE WHERE THE ACCUMULATED VPD CAN
BE ZEROED OUT.
SET SYSTEM
This Mode is used to set the following:
Number of VPD Sensors:
1 or 2
Number of Stations:
1 to 12 (Up to 24 with the EXPANSION)
Number of Aging Groups: 1 to 6
Number of Disable Groups: 1 to 4
Max Number of Stations ON: 1 to 24, please set for 4 or less to prevent over taxing
transformer
End Of Sched Alarm:
NO or YES
Set Clock:
(enter correct time)
8. Month/Day/Year:
(enter date)
9. Sunrise & Sunset:
(enter correct times)
10. Light Sensor Sensitivity: Low/Med/High
11. Custom System ID:
Off/Display/Program
12. Review I/O Assignments: NO or YES
13. Remote ID Code:
0 to 31
14. Temperature Read in:
F or C
This Mode provides a lot of information to the grower, once the stations have been entered
into the unit. After all stations are set up and the SET SYSTEM Mode is activated, the
display will read, SHOW STATUS? Answer YES to see information on each station. This
information includes Station Name, Whether the Station is Off or On, Station Target,
Station Accumulated VPD, and amount of time left on an active watering cycle.
Note: Answer all questions with only the number of stations, crop aging groups and
disable groups that are currently being set up. This will prevent the unit from asking
for information about stations, crop age groups, and disable groups that do not exist.
SET STATION
This Mode is used to set up each of the stations. Choose whether the station will be used
for Misting, Irrigation, Auxiliary or Not Used. Then choose from Fixed Target or Crop
Age Group, Disable Group, VPD Sensor or Manual VPD, Crop Day, and the amount of
ON TIME for the device attached to the station.
SET CROP AGING TARGET GROUPS
This Mode is used to set up Crop Aging. Set up to six different groups. Crop Age Groups
can be set up for both Misting and Irrigation stations with either Increasing or Decreasing
Targets. The 20%, 40%, 60%, and 80% midpoint targets for the Crop Age Group can be
changed. If the 20% target is changed, this will affect all targets from the Day 2 Target to
the target for the day prior to the 40% midpoint target. If the 40% midpoint target is
changed, this will affect all targets from the target the day after the 20% midpoint target to
the target for the day prior to the 60% midpoint target. 60% and 80% midpoint changes
Содержание WATER PRO