LIMITED WARRANTY 

 

Phytotronics Inc. warrants that all of the products Phytotronics Inc. manufactures are 
free from defects at the time of shipment by Phytotronics Inc. This warranty covers 
defects in workmanship and materials. No warranty is extended on any parts, materials, 
or components manufactured by others and purchased by Phytotronics Inc., and any 
warranty on these materials is limited to the warranty supplied by the original 
manufacturer or supplier of said products only. This warranty excludes any and all 
damages cause by power surges, lightning, installation by unqualified individuals, 
damage by misuse or neglect, shipment damage, alterations to original manufacturing, 
and improper installation or use for any reason than intended by manufacturer. This 
warranty may not be altered in any manner except with the written authorization of one 
the officers or owners of Phytotronics Inc. The only and sole liability of Phytotronics Inc. 
under this warranty is limited to repairing, replacing or the issuance of credit for any 
products returned to Phytotronics Inc., during the warranty period of twelve (12) months 
from date of shipment. This warranty is specifically conditioned upon Phytotronics Inc. 
being notified in writing promptly upon discovery of any product defects by the buyer or 
end user. The product must then be returned prepaid to Phytotronics Inc. within the 
twelve month warranty period for inspection by Phytotronics Inc. Upon inspection of said 
product, Phytotronics Inc. will notify buyer or end user of its findings. At Phytotronics 
Inc. sole discretion, the product will be replaced, repaired or a credit will be issued for 
the original sale price of the product, provided that damage has not occurred due to 
misuse, neglect, improper use or installation as outlined above, shipping damages or 
accident. 

 

Phytotronics  Inc.  SHALL  NOT  BE  LIABLE  FOR  ANY  DAMAGES  BEYOND  THE 
ACTUAL  ORIGINAL  COST  OF  THEIR  PRODUCT  EITHER  DIRECTLY  OR 
INDIRECTLY ARISING FROM DEFECTIVE PRODUCTS OR WORKMANSHIP.

 

 

Содержание WATER PRO

Страница 1: ...13688 Rider Trl N Earth City MO 63045 PHONE 314 770 0717 FAX 314 506 4587 www phytotronics com Revision 1 2 10 15 2021 Water Pro VPD Misting and Irrigation Control...

Страница 2: ...er ELECTRICAL CIRCUIT The electrical circuit that feeds the machine tool transformer must have no other loads connected to it This will prevent damaging surges from other related electrical devices Fo...

Страница 3: ...from your solenoid valves 24VAC type to the WATER PRO EXPANSION module plugs 3 Make sure all plugs are secured into the WATER PRO EXPANSION module then turn the screw locking the panel in its enclosur...

Страница 4: ...vating the next Output Station FEATURES OF THE EQUIPMENT INPUTS and OUTPUTS The Sensor Inputs to the WATER PRO are as follows 1 Air Temperature 1 from VPD Sensor 1 2 Leaf Temperature 1 from VPD Sensor...

Страница 5: ...r Air Temperature 1 Leaf Temperature 1 Relative Humidity 1 Air Temperature 2 If optional sensor installed Leaf Temperature 2 If optional sensor installed Relative Humidity 2 If optional sensor install...

Страница 6: ...of time left on an active watering cycle Note Answer all questions with only the number of stations crop aging groups and disable groups that are currently being set up This will prevent the unit fro...

Страница 7: ...nrise When attaching the Disable Group to an irrigation station the irrigation station will disable for the amount of time called for in the Disable Group prior to Sunset No matter what type of statio...

Страница 8: ...wo mists This gives the VPD per minute For each daily target calculate how much time between each misting for that specific day if the environmental conditions were identical to the first target Multi...

Страница 9: ...lant must have water After watering the plant the process starts all over again Just what is VPD and how does it relate to plants To understand VPD we must understand the following 1 How water moves t...

Страница 10: ...he VPD accumulation The Set System Mode is where the accumulated VPD information is displayed as it approaches the target that was entered in the Set Station Mode When a station zone needs to be water...

Страница 11: ...be 2 When the timer or other device waters the plants go into the Manual Mode and Trigger the Station with the high fixed target To do this a Use the RUN SET switch to go into the Manual Mode b Use th...

Страница 12: ...get If attempting to determine a new target enter a high target 1000 for a misting station and 50 000 for an irrigation station Use the VALUE and the PRIOR NEXT switches to enter this target Refer to...

Страница 13: ...program or to Stop Watering Use the VALUE switch to enter this choice 36 Push the PRIOR NEXT switch to NEXT to go to the next question 37 Choose whether or not to use a DISABLE program Use the VALUE...

Страница 14: ...go to the next question 11 Choose the final day target If attempting to determine this target refer to the section How To Determine Correct Watering Targets 12 Push the PRIOR NEXT switch to NEXT to go...

Страница 15: ...sunrise 8 Push the PRIOR NEXT switch to NEXT to go to the next question WARNING If this is the FIRST TIME this crop age program has been set up choose Yes Reset First The WATER PRO resets the targets...

Страница 16: ...lations Only in the Manual Mode can the VPD Accumulation for a station be zeroed out NOTE USE OF THE ON OFF AUTO SWITCHES DO NOT ZERO OUT VPD ACCUMULATIONS Example 2 TRIG STATION 1 If the zone connect...

Страница 17: ...17...

Страница 18: ...only and sole liability of Phytotronics Inc under this warranty is limited to repairing replacing or the issuance of credit for any products returned to Phytotronics Inc during the warranty period of...

Отзывы: