phyCORE-TC1796
42
©
PHYTEC Meßtechnik GmbH 2009 L-719e_2
7.4
USB to UART Bridge (U10)
One USB to UART Bridge CP2102 is located on the phyCORE-
TC1796 at U10.
The CP2102 is a highly-integrated USB-to-UART Bridge Controller
providing a solution to transmit and receive UART signals over USB
from a Host PC. A Royalty-free Virtual COM Port (VCP) device
drivers provided by the chip- manufacturer allow a CP2102-based
product to appear as a COM port to PC applications.
5V Supply voltage from USB VBUS must be applied on phyCORE-
connector X3C30 because the CP2102 bus-powered on the
phyCORE-TC1796.
The TC1796 ASC0 can be connected to communicate over USB to a
Host PC. This is done by closing jumper J12 and J13
(open per
default)
so that RxD0 (P5.0) of the TC1796 is connected to the
UART Transmit of CP2102 and TxD0 (P5.1) of the TC1796 is
connected to the (UART Receive).
Please refer to jumper J12 and jumper J13 in section 3
Furthermore it is possible to activate the /Boot and /PORST by using
the R232 handshake Output Signals RTS (Request to Send) and DTR
(Data Terminal Ready) provided by the CP2102.
RTS can control the /Boot signal (used for alternative Bootmode )
DTS can control the /PORST signal (system Reset)
In order to use this feature the optional resistors J22 an J23 must be
populated with 0R (unpopulated per default)
Caution:
USB to UART Bridge is NOT connected to the TxD0 and RxD0 in
the standard phyCORE TC1796 module configuration.
Содержание phyCORE-TC1796
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE TC1796 Hardware Manual Edition May 2009...
Страница 6: ......
Страница 14: ...phyCORE TC1796 8 PHYTEC Me technik GmbH 2009 L 719e_2 Figure 3 View of the phyCORE TC1796 Connector Side...
Страница 29: ...Jumpers PHYTEC Me technik GmbH 2009 L 719e_2 23 Figure 7 Location of the Jumpers Connector Side...
Страница 35: ...Jumpers PHYTEC Me technik GmbH 2009 L 719e_2 29...
Страница 65: ...Published by PHYTEC Me technik GmbH 2009 Ordering No L 719e_2 Printed in Germany...