The phyCARD-M on the phyBASE
©
PHYTEC Messtechnik GmbH 2010 L-750e_1
85
Three different power states are possible RUN, OFF and SUSPEND.
•
During RUN all supply voltages except VSTBY are on. This
means that the phyCARD-M is supplied by VCC_PHYCARD.
•
In OFF state all supply voltages are turned off. Only the standby
voltage (VCC3V3STBY) of the phyBASE itself is still available
to supply the PLD, the RTC and to provide a high-level voltage
for the Reset and Power switch.
•
In SUSPEND mode only the standby voltage VSTBY for the
phyCARD-M and the standby voltage (VCC3V3STBY) of the
phyBASE itself are generated. This means the phyCARD-M is
supplied only by VSTBY.
The RUN and OFF state can be entered using the power button S2 as
described in the gray box above. It is also possible to enter OFF state
with the help of the phyCARD's nPower_off signal (GPIO2_30 at T5
of the i.MX35). To enter OFF state signal nPower_off must be active
(low).
SUSPEND state can be entered using signal nSuspend_to_RAM at pin
X2A26B of the phyCARD Connector (GPIO2_29 at V2 of the
i.MX35). nSuspend_to_RAM must be active (low) for at least 500ms.