10.0   REPAIRS AND RECALIBRATION

10.1   In the event that a Thermalert Monitoring Thermometer is to be returned for repair and
recalibration, please pack it with care and send it prepaid to:

Physitemp Instruments, Inc.
Service Department
154 Huron Avenue
Clifton, NJ 07013 USA

Please include with the instrument:

(1)  A note describing any problems encountered.
(2)  The name and telephone number of the user or other person we can contact.
(3)  The complete return address for shipping.

10.2   A Service Manual for the TH-5 is available at additional charge.  It includes schematic,
component locator, trouble-shooting guide and complete calibration instructions. Specified test
equipment is required for recalibration or other servicing. Consult Physitemp Inc. for further
service information by telephone at:

Tel:

973-779-5577

Fax:

973-779-5954

E-mail:

[email protected]

10.3   Physitemp Instruments Inc. warrants this instrument to be free from defects in material
and workmanship for 12 months from date of shipment.  Repair or replacement will be made at
no charge at the discretion of Physitemp if the defect is not the result of misuse or abuse.
Physitemp accepts no consequential liabilty for delay in delivery, alleged faulty performance of
the product, or for any other cause. 

Cables and probes are considered expendable and are not covered by this warranty.  See sepa-
rate warranty enclosed with probe.

For your protection, please pack returned items carefully, and insure them against possible dam-
age or loss in transit.  Physitemp will not be responsible for damage resulting from careless or
inadequate packaging. Pleasereturn freight prepaid. 

During the warranty period, the instrument may also be returned for a free calibration check.

11

Содержание TH-5

Страница 1: ...L INSTALLATION 3 0 PRECAUTIONS 4 0 DIRECTIONS FOR USE 5 0 REPLACING BATTERIES 6 0 CHECKING CALIBRATION 7 0 USE OF THERMALERT WITH CHART RECORDER 8 0 SPECIFICATIONS 9 0 TEMPERATURE MEASUREMENT WITH THE...

Страница 2: ......

Страница 3: ...rature monitoring system use suitable accepted technique during eletro surgical procedures to minimize the possibility that the probe cable will serve as an alternate path for radio frequency current...

Страница 4: ...e or probe Check connection If this is good replace probe A flashing colon in the center of the display signifies low battery alert Accurate readings will still be obtained and it is not necessary to...

Страница 5: ...3 4 full Add distilled water Leave for 30 minutes to allow temperature to stabilize stirring periodically b Immerse the standard mercury in glass thermometer in the ice bath to the immersion mark on t...

Страница 6: ...ent display and possible probe error readings should agree within the limits noted in Section 9 7 This means as an approximate rule of thumb that differences between standard and instrument readings s...

Страница 7: ...ded input binding post If a patient is connected to faulty AC powered equipment and becomes live a leakage path to ground would exist between the sensor probe and the recorder Current safety limits co...

Страница 8: ...y may be used Carbon Zinc cells are not recommended Battery Life Expectancy 1200 hours continuous alkaline Analog Output Optional extra approx 25mV C Size 3 H x 6 1 W x 6 1 4 D Weight 2 1 2 lbs Leakag...

Страница 9: ...raceable to NIST calibrations e Low cost users can even make their own sensors f Microscopic size when needed as in Physitemp microprobes g Nearly instant response h Better measurement accuracy due to...

Страница 10: ...This simple precaution must always be taken 9 9 Measurements of Air Temperature Temperature can vary widely in different parts of a room differences of at least several degrees will usually be noted W...

Страница 11: ...information by telephone at Tel 973 779 5577 Fax 973 779 5954 E mail physitemp aol com 10 3 Physitemp Instruments Inc warrants this instrument to be free from defects in material and workmanship for...

Отзывы: