15
Fuel System
The PH52W fuel pump and fuel system are the heart of the heater. The fuel pump not only delivers fuel to
the heater but also controls the amount of fuel delivered. The pump is designed to operate like an electric
solenoid and works using electric pulses. Each time it is energized, it provides a measured dose of fuel. It
is critical to the heater’s operation to stay within parameters outlined below and only use the components
provided. (Figure F1)
System Layout & Considerations
• Keep the length of the fuel system short as possible.
• Mount the fuel pump as close to the fuel pickup as possible (pump pushes better than it sucks).
• Minimize vertical rise.
• Mount the fuel pump in a protected location away from road spray.
• Choose a mounting location for the fuel pickup pipe that is close to the heater and offers installation
access.
• Design your fuel system so that Figure F1 fuel line limits are not exceeded.
*Figure F1
1. Heater
2. Fuel Pickup Pipe
3. Fuel Metering Pump
4. Fuel Tank
5. 9-11 mm Clamp
6. 5.0 mm Rubber Fuel Line
7. 5.0 mm Rubber Connector
8. 3.0 mm Clear Plastic Fuel Line
Max. 2 M (12’)
Max. 6 M (20’)
Max. 1/2 M (18”)
Max. 1 M (6, 6”)