PHOTOWATT PW60HT-CB-XF Скачать руководство пользователя страница 1

INSTALLATION  MANUAL

OF BIFACIAL MODULES

For professional use only

Содержание PW60HT-CB-XF

Страница 1: ...INSTALLATION MANUAL OF BIFACIAL MODULES For professional use only...

Страница 2: ...CAL SPECIFICATIONS 3 4 0 UNPACKING AND STORAGE 5 5 0 MODULE INSTALLATION 6 5 1 MODULE WIRING 7 5 2 GROUNDING 10 6 0 MOUNTING INSTRUCTIONS 11 6 1 MOUNTING METHODS FOR FRAME BIFACIAL MODULE BOLTING 12 6...

Страница 3: ...s pass direct current DC when exposed to sunlight or other light sources Contact with electrically active parts of the module such as terminals can result in injury or death irrespective of whether or...

Страница 4: ...to 68 1 02 19 to 15 67 to 59 1 04 14 to 10 58 to 50 1 06 9 to 5 49 to 41 1 08 4 to 0 40 to 32 1 to 5 31 to 23 1 10 1 12 6 to 10 22 to 14 1 14 11 to 15 13 to 5 1 16 16 to 20 4 to 4 1 18 21 to 25 5 to 1...

Страница 5: ...ed to moisture or sunlight like using connector endcaps Connector endcaps are available upon request When unloading module pallets from containers please use a fork lift to remove the module pallets a...

Страница 6: ...ly specified in the installation instructions and UL2703 certification of the mounting system supplier ENVIRONMENTAL CONDITIONS The module is intended for use in general open air cli mates as defined...

Страница 7: ...r optimizing the power generation of the rear side of bifacial modules obstacles between modules and the mounting ground should be avoided as much as possible Constant shading conditions can affect mo...

Страница 8: ...PW72LHT CB XF Cable length per lead 1400 mm PW60HT CB XF Cable length per lead 1250 mm NOTICE Adjacent modules in the same row need to be rotated 180 degrees for proper installation Portrait installa...

Страница 9: ...mm 1400 mm jumper cable NOTICE Modules in adjacent rows should be rotated 180 degrees for proper installation Portrait installation one row Leap frog for single axis tracker PW72HT CB XF Cable length...

Страница 10: ...ties Protect exposed cables from damage by taking appropriate precautions e g plac ing them inside a metallic raceway like EMT conduit Avoid exposure to direct sunlight A minimum bending radius of 60m...

Страница 11: ...ating the equivalent maximum authorized design loads Project design loads depend on construction applicable stan dards location and local climate Determination of the design loads is the responsibilit...

Страница 12: ...d on actual module frame height For bifacial module with 30 mm frame height our recommended maximum bolt length is 20 mm in order to properly insert the bolts through the mounting hole The system desi...

Страница 13: ...r holes installation method B Middle four holes installation method A Middle four holes installation method B PW72HT CB XF PW72LHT CB XF 5400Pa 2400Pa 3600Pa 2400Pa PW60HT CB XF 5400Pa 2400Pa 3600Pa 2...

Страница 14: ...alculations and for proper design of support structure The mounting rails shall be designed to limit as much as possible shade on module rear side cells EDF ENR PWT s warranty may be void in cases whe...

Страница 15: ...E Module Types Max Mechanical Load Pa 5400 3600 A Range mm PW60HT CB XF 270 380 PW72HT CB XF 410 490 PW72LHT CB XF 410 490 6 2 2 CLAMP MOUNTING ON LONG SIDE OF FRAME AND RAILS PARALLEL TO THE LONG SID...

Страница 16: ...d be at least 40mm TRACKER 1P BOLTING METHOD Install and tighten the module clamps to the mount ing rails using the torque stated by the mounting hardware manufacturer M6 X 1 1 4 bolt and nut are used...

Страница 17: ...ect modules for cracks damage and loose connections The voltage and current present in an array during daylight hours are sufficient to cause a lethal electri cal shock Ensure that the circuit is disc...

Страница 18: ...he existing conditions Method B Wet cleaning If excessive soiling is present on the module surface a non conductive brush sponge or other mild agi tating method may be used with caution Ensure that an...