26
Name
Address
Size
Description
I_COL
38
4
Column load current
I_COLAMP
39
4
Column amplifier current
I_ADC
39
4
ADC comparator current
I_COMPINV
40
4
ADC output invertor current limit
I_ADCPC
40
4
ADC precharge voltage buffer current
I_LVDS_REC
41
4
LVDS receiver current
I_LVDS_DRIV
41
4
LVDS driver current
V_ADCPC
42
7
ADC precharge voltage
V_ADCCLAMP
43
7
ADC clamp voltage
RST_LOW
44
7
Pixel reset low voltage
VTX_LOW0
45
7
Set the saturation/anti‐blooming level for
the
integration after slope 3.
VTX_LOW1
46
7
Set the reset level for the third slope. Change this
register to control the position of the knee point
between slope 2 and slope 3. Set the
saturation/anti‐blooming level in case of dual
slope operation.
VTX_LOW2
47
7
Set the reset level for the second slope. Change
this
register to control the position of the knee point
between slope 1 and slope 2. Set the
saturation/anti‐blooming level in case of
single slope operation.
V_VRAMP2
48
7
Starting voltage of 2nd ramp in AD conversion
V_VRAMP1
49
7
Starting voltage of 1st ramp in AD conversion
V_VREF
50
7
Reference voltage for the column amplifier