39
Value 2‐ overlay 25% transparent
Value 3‐ overlay is opaque
o
[2]: XOR enable‐ XOR’s MSB of video data with 1 to provide 50% contrast
between the overlay and the video data
o
[3]: blink enable
3.1.3.13
AGC
Commands
A list of valid AGC functions and current value can be queried from the camera by sending
the following command:
AGC
status
<CR><LF>
All valid serial command shown in Table 17 should be sent as:
AGC
<Command>
<Optional
Payload><CR><LF>
Table
17
AGC
Commands
Command
Optional
Payload
Description
status
Display the AGC commands and settings
agcupdinterva
XX
Number of histogram to collect before
doing an AGC update
saturationlev
XXX
Sets the digital value at which a pixel is
considered saturated
bdeltalim
XXX
Sets the minimum brightness delta between
the high and low limit of the cumulative
histogram in conjunction with the
“saturationlev” to determine if the sensor
output is saturated under normal operation
bhidnlim
XXX
Increase exposure value if “bhipcagc” is
lower than this digital output value
bhipcagc
XX
Mean brightness high percentage of the
cumulative histogram to remap that AGC
algorithm tries to maintain to “bhitgt”
digital value
blopcagc
XX
Mean brightness low percentage of the
cumulative histogram to remap that AGC
algorithm tries to maintain to 0 digital