19
Command
Optional
Payload
Description
16
Set the line noise filter to use 16 columns
cs
vbo
[0‐255]
Sets the video black offset when the line
noise filter is enabled
cs
active
0
1
Clears the sensor active signal to the CMOS
image sensor
Set the sensor active signal to the CMOS
image sensor
cs
dumptbl
Displays camera sensor register default
table data to console (store in camera)
cs
dump
Displays current sensor register settings
read from sensor on the console
cs
rd
xx
Reads camera sensor register address xx
and display value on the console
cs
wr
xx dd
Write camera sensor register address xx
with value dd
cs
save
user
Save current sensor register settings as
power on default (the gain and exposure
settings will be ignored and the value
entered in under the agc setup will be used)
A list of all possible registers for the “cs wr” and “cs rd” is given in Table 8. It is
recommended to refer to the LYNX CMOS datasheet for further explanation of the sensor
register settings. Typical usage of the “cs wr” and “cs rd” command should be as follows:
Writing
register:
CS
wr
<Address>
<Value><CR><LF>
Reading
register
CS
rd
<Address><CR><LF>
Table
8
CMOS
Sensor
Registers
Name
Address
Size
Description