
10
High Dynamic Range Mode (HDR)
10.1
Multiple Slope Mode (High Dynamic Range)
The Multiple Slope High Dynamic Range (HDR) mode is a special integration mode that
increases the dynamic range of the pixels, and thus avoids the saturation of the pixels in many
cases. The multiple slope mode is also called multiple slope mode or piecewise linear mode.
The multiple slope mode clips illuminated pixels which reach a programmable voltage, while
leaving the darker pixels untouched (see Fig. 10.1). The clipping level can be adjusted once (2
slopes) or twice (3 slopes) within the exposure time.
Parameters:
Multislope_Mode
There are 3 predefined multiple slope parameter sets:
LowCompression
,
NormalCompression
and
HighCompression
. If
Multislope_Mode
is set to
UserDefined
then the
individual parameters can be set to user defined values.
Multislope_NrSlopes
Number of slopes.
Multislope_NrSlopes
=2: 2 slopes with only kneepoint B.
Multislope_NrSlopes
=3: 3 slopes with kneepoints A and B.
Multislope_Value1
Corresponds to Vlow1: the higher the value, the higher the compression.
Multislope_Time1
Time corresponding to kneepoint B. The value is the fraction (per mill) of
the total exposure time.
Multislope_Value2
Corresponds to Vlow2: the higher the value, the higher the compression.
This value is ignored if
Multislope_NrSlopes
=2.
Multislope_Time2
Time corresponding to kneepoint A. The value is the fraction (per mill) of
the total exposure time. This value is ignored if
Multislope_NrSlopes
=2.
The red line in Fig. 10.1 shows a pixel with high illumination. Without the multiple slope
mode, the pixel would have reached its saturated value. With multiple slope mode, the pixel
reaches value P1 which is below the saturation value. The resulting pixel response in this case is
shown in Fig. 10.2. The blue line (P2) shows a pixel with low illumination. Its value never
reaches Vlow2 or Vlow1 at the kneepoints and the resulting response is linear.
Changing the Exposure time or
Multislope_Time1
and
Multislope_Time2
requires
the Acquisition to be stopped when Multislope Mode is active. Otherwise, the
first image after updating any of these values could be prone to artefacts.
MAN085 04/2021 V1.3
69 of 151
Содержание Luxima DR4-D1280-L01-FB
Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...
Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...