Photon Focus Luxima DR4-D1280-L01-FB Скачать руководство пользователя страница 132

18 Warranty

8.

Avoid cleaning the sensor with improper methods. Follow the instructions in the
corresponding chapter of this manual.

9.

Transport and store the camera in its original packaging only and protect the sensor and
the lens mount with a camera body cap.

10. Read the manual carefully before installing and using the camera.

132 of 151

MAN085 04/2021 V1.3

Содержание Luxima DR4-D1280-L01-FB

Страница 1: ...D1280 L01 FB DR4 D1280 L01 G2 DR4 D1280 L01 GT available on request DR4 D1280 L01 FB available on request MV4 D1952 L01 G2 available on request MV4 D1952 L01 GT MV4 D1952 L01 FB available on request...

Страница 2: ...is assumed by Photonfocus AG for its use Photonfocus AG reserves the right to make changes to this information without notice Reproduction of this manual in whole or in part by any means is prohibite...

Страница 3: ...ure 25 4 1 3 Image Acquisition Frame and Exposure Control Parameters 26 4 1 4 Image Acquisition Frame and Exposure Trigger 27 4 1 5 Image Acquisition Frame and Exposure Status 27 4 2 Acquisition Contr...

Страница 4: ...t Source 45 5 1 6 Counter Trigger Source 46 5 1 7 Counter Reset Source 47 5 2 Timer 49 5 2 1 Timer Usage 49 5 2 2 Timer Status 49 5 2 3 Timer Active Start and End Signal 50 5 2 4 Timer Reset 50 5 2 5...

Страница 5: ...ages 87 12 8 1 Ramp 87 12 8 2 LFSR 87 12 8 3 Troubleshooting using the LFSR 87 12 9 Status Line and Image Information 89 12 9 1 Image Average Value 89 12 9 2 Status Line Format 89 12 9 3 Camera Type C...

Страница 6: ...ns 130 18 Warranty 131 18 1 Warranty Terms 131 18 2 Warranty Claim 131 18 3 Breach of Warranty 131 19 Support and Repair 133 19 1 Technical Support 133 19 2 Repair and obtaining an RMA Number 133 19 3...

Страница 7: ...C 4 4 User defined LUT settings 148 C 4 5 Predefined LUT settings 148 C 5 Encoder 148 C 5 1 Configuration of the encoder AB signals 149 C 5 2 Configuration of the encoder Z signal 149 C 5 3 Configura...

Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...

Страница 9: ...TRUCTIONS FOR USE BEFORE OPERATING THE CAMERA STORE THE INSTRUCTIONS FOR USE FOR FURTHER READING Photonfocus AG Bahnhofplatz 10 CH 8853 Lachen SZ Switzerland www photonfocus com info photonfocus com 4...

Страница 10: ...55 451 00 00 Email support photonfocus com Table 1 1 Photonfocus Contact 1 4 Sales Offices Photonfocus products are available through an extensive international distribution network and through our k...

Страница 11: ...er rors 1 6 Legend In this documentation the reader s attention is drawn to the following icons Important note additional information Important instructions General warning possible component damage h...

Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...

Страница 13: ...ure 2 1 Camera naming convention Prefix1 Camera platform and usage prefix The following prefix are available for this camera series MV4 with form factor 59mmx59mm DR cameras have DR4 as Prefix1 Prefix...

Страница 14: ...Ethernet Fibre 1 3 MP monochrome standard camera MV4 D1952 L01 G2 2 1952 x 1080 53 fps 1 Gigabit Ethernet 2 1 MP monochrome standard camera MV4 D1952 L01 GT 1952 x 1080 581 fps 1 10 Gigabit Ethernet...

Страница 15: ...aximal resolution 53 fps GigE and 581 fps 10GigE I O capabilities 4x Isolated inputs or shaft encoder A B Z Y interface RS422 TTL D HTL HTL 3x Isolated outputs 2x open drain 1x TTL highspeed Up to 8 r...

Страница 16: ...ecification Figure 3 1 Photonfocus MV4 Luxima GigE camera series Figure 3 2 Photonfocus MV4 Luxima 10 GigE camera series Figure 3 3 Photonfocus MV4 Luxima 10 GigE fibre camera series 16 of 151 MAN085...

Страница 17: ...3 1 Introduction Figure 3 4 Photonfocus MV4 Luxima 10 GigE ruggedized fibre camera series MAN085 04 2021 V1 3 17 of 151...

Страница 18: ...liant Camera Control GigE Vision Suite Trigger Modes Software Trigger External isolated trigger inputs A B Trigger Features Greyscale colour resolution 12 bit 10 bit 8 bit Region of Interest ROI Up to...

Страница 19: ...urve Linear Piecewise linear multiple slope Shutter mode global shutter Sensor bit depth 12 bit Maximal frame rate MV4 GigE 1 85 fps 53 fps Maximal frame rate MV4 10GigE 1 935 fps 581 fps Maximal fram...

Страница 20: ...I O Inputs 4x Isolated inputs or shaft encoder A B Z Y interface RS422 TTL D HTL HTL I O Outputs 3x Isolated 2x open drain 1x TTL highspeed I O Control 1x Isolated RS485 Dimensions 59 x 59 x 89 6 mm3...

Страница 21: ...ter available I O Inputs 4x Isolated inputs or shaft encoder A B Z Y interface RS422 TTL D HTL HTL I O Outputs 3x Isolated 2x open drain 1x TTL highspeed I O Control 1x Isolated RS485 Dimensions 59 x...

Страница 22: ...mera Control Output Signal Output Power Single Ended 0 5 W ESD Contact Discharge Camera Control Signals 10 kV ESD Air Discharge Camera Control Signals 7 kV Fast Transients Bursts Data and Camera Contr...

Страница 23: ...LineIn0 LineIn1 LineIn2 Differential Input Voltage Logic Level Fault Condition VID 2V High No Fault 1 2V VID 2V High Indeterminate 0 9V VID 0 9V Indeterminate Low Differential Input Voltage Fault 2V V...

Страница 24: ...50 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 Wavelength nm LUX1310 Mono Figure 3 5 Quantum efficiency QE of the LUX1310 monochrome image sensors with micro lenses and cover glass 0 10 20...

Страница 25: ...ure time and an image read out A burst of frame is defined as a capture of a group of one or many frames within an acquisition An acquisition can be grouped in N single frames or N burst of frames 4 1...

Страница 26: ...GigE interface to the camera with low latency and low jitter I O Control The I O control unit manages physical camera inputs and outputs and LED A switch matrix within this block allows connecting int...

Страница 27: ...ignals or from a pulse generated by a software command Each of these triggers can be switched on or off individually The camera generates the triggers pulses internally which are switched off The foll...

Страница 28: ...n number of frames which are defined by acquisition frame count parameter or when the acquisition stop command is executed Acquisition Mode Continuous Frame When the acquisition is started the camera...

Страница 29: ...tate Acquisition Active and is ready to capture frames Acquisition Start Trigger Mode off As soon as the acquisition is started by executing of the acquisition start command the camera goes immediatel...

Страница 30: ...cquisition Trigger Wait An asserted acquisition trigger wait indicates that the acquisition control is waiting for an acquisition start trigger see Section 4 2 3 Acquisition Active Acquisition active...

Страница 31: ...Frame Start Trigger Mode off The frame start triggers are ignored The camera runs in free running mode when the mode of both triggers the frame start trigger and frame burst start trigger is set to o...

Страница 32: ...st Fig 4 7 shows the procedure of a burst of frames and a single frame capture The Acquisition start and end trigger mode is on So the camera waits for an acquisition trigger once the acquisition comm...

Страница 33: ...erted frame trigger wait indicates that the frame control is waiting for a frame start trigger see Section 4 3 1 frame burst start trigger see Section 4 3 2 or an exposure start trigger see Section 4...

Страница 34: ...exposure start and exposure end triggers see Section 4 4 2 and Section 4 4 3 for more information 4 4 2 Exposure Start Trigger The exposure start trigger is used to start an exposure Exposure Start Tr...

Страница 35: ...i o n S t o p E x p o s u r e 1 R e a d O u t 1 F r a m e 1 E x p o s u r e S t a r t T r i g g e r 1 E x p o s u r e E n d T r i g g e r 1 F r a m e A c t i v e E x p o s u r e 2 R e a d O u t 2 F r...

Страница 36: ...a m e S t a r t T r i g g e r 1 F r a m e S t a r t T r i g g e r 2 F r a m e S t a r t T r i g g e r N F r a m e T r i g g e r W a i t F r a m e T r i g g e r W a i t F r a m e T r i g g e r W a i t...

Страница 37: ...r i g g e r s w i t h i n t h i s p e r i o d a r e i g n o r e d E v e r y t r i g g e r w i l l b e i n d i c a t e d b y a n M i s s e d T r i g g e r e v e n t Figure 4 11 Overlapped Image acquis...

Страница 38: ...q u i s i t i o n E n d T r i g g e r D e l a y D i v i d e r M o d e O n O f f A c t i v a t i o n R i s i n g E d g e F a l l i n g E d g e B o t h E d g e s S o u r c e S o f t w a r e A c q u i s...

Страница 39: ...signal is generated by the encoder see Chapter 6 for more information about the encoder Action A trigger signal is generated by the action control block see Chapter 8 for more information about the ac...

Страница 40: ...es A division factor of 1 processes every incoming trigger A division factor of 2 processes every second trigger and so on 4 6 6 Trigger Delay The trigger delay lets the user specify a delay that will...

Страница 41: ...start a procedure Acquisition Start Trigger Acquisition End Trigger Frame Start Trigger Frame Burst Start Trigger Frame Burst End Trigger Exposure Start Trigger Exposure End Trigger Counter Trigger C...

Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...

Страница 43: ...ent and counter reset signals This section describes the configuration and the function of the counters Fig 5 1 shows the structure of one counter Along with the counter function itself it contains a...

Страница 44: ...eceived Once the counter is in the state overflow it has to be reset by software or by counter reset signal in order to recover it from this state 5 1 3 Counter Active Start and End Signal Each counte...

Страница 45: ...t Counts the number of frame burst start events Frame Burst End Counts the number of frame burst end events Exposure Start Counts the number of exposure start events Exposure End Counts the number of...

Страница 46: ...unter counts rising edges on the selected line input Falling Edge Counter counts falling edges on the selected line input Both Edges Counter counts both edges on the selected line input Activation con...

Страница 47: ...on which needs to be set accordingly Following configuration values are available Rising Edge Counter starts with the rising edge on the selected line input Falling Edge Counter starts with the fallin...

Страница 48: ...sets with the reception of the chosen counter end event Timer 0 3 Start Resets with the reception of the chosen timer start event Timer 0 3 End Resets with the reception of the chosen timer end event...

Страница 49: ...elay and timer duration value needs to be configured accordingly When a timer trigger source is selected the timer is waiting for a trigger signal Once this trigger signal has been received the timer...

Страница 50: ...o reset and to start the timer The following list of signals are available Off Disables the timer trigger Acquisition Trigger Starts with the reception of the acquisition trigger event Acquisition Sta...

Страница 51: ...activation configuration which needs to be set accordingly Following configuration values are available Rising Edge Timer starts with the rising edge on the selected line input Falling Edge Timer sta...

Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...

Страница 53: ...6 1 shows the structure of the encoder The trigger sources for the A and B inputs can be mapped to any of the line inputs of the camera while the reset source can also be mapped to a multitude of othe...

Страница 54: ...e PostionUp and Down modes a watermark counter is used The counter resets whenever the output mode changes the encoder is reset or a new start value is written See Fig 6 3 for a comparison of the mode...

Страница 55: ...of the frame trigger Frame Start Resets with the reception of the frame start event Frame End Resets with the reception of the frame end event Frame Burst Start Resets with the reception of the frame...

Страница 56: ...ne input Level High Resets the encoder as long as the level is high The encoder remains in reset state until the level is low again Level Low Resets the encoder as long as the level is low The encoder...

Страница 57: ...an invert this signal and its current status can be read by software I n p u t S i g n a l P a t h L i n e 0 S t a t u s I n v e r t L i n e I n 0 I n p u t S i g n a l P a t h L i n e 1 I n p u t S i...

Страница 58: ...e O u t 2 L i n e O u t 1 L i n e O u t 0 L E D 0 Figure 7 2 Output Signal Path Following signals are available and can be selected for the output Input Lines Counter Active Status Timer Active Status...

Страница 59: ...d Usage Each action command message comes with the following key and mask information which is necessary to validate the requested action signal ActionUnconditionalMode Enables the unconditional actio...

Страница 60: ...8 Action Control 8 2 Action Control Output The action output signals can be used to trigger other blocks like counter timer acquisition frame or exposure control 60 of 151 MAN085 04 2021 V1 3...

Страница 61: ...he amount of image data and increase the frame rate An application example for using multiple regions of interest MROI is a laser triangulation system with several laser lines The multiple ROIs are jo...

Страница 62: ...age frame rate M R O I 0 M R O I 1 M R O I 2 0 0 0 0 x m a x y m a x R O I M R O I 0 M R O I 1 M R O I 2 R O I x m a x y m a x R O I X R O I W R O I Y R O I H R O I X R O I W M R O I 0 Y M R O I 0 H M...

Страница 63: ...9 2 Multiple Regions of Interest Figure 9 2 Multiple Regions of Interest with 5 ROIs MAN085 04 2021 V1 3 63 of 151...

Страница 64: ...a 640x54 region need to be readout and a much higher frame rate is possible which can t be achieved without using MROI 6 4 0 p i x e l 0 0 x m a x y m a x 2 0 p i x e l 2 6 p i x e l 2 p i x e l 2 p i...

Страница 65: ...d read out time and higher frame rate respectively Decimation can also be used together with ROI or MROI In this case every ROI should have a height that is a multiple of the decimation setting E g if...

Страница 66: ...t Available Enabled or Disabled X X X X X DR4 D1280 L01 G2 Enabled Enabled or Disabled X Disabled Enabled or Disabled X X X X X DR4 D1280 L01 GT Enabled Enabled or Disabled X Disabled Enabled or Disab...

Страница 67: ...Decimation monochrome cameras 0 0 x m a x y m a x R O I Figure 9 5 Decimation and ROI M R O I 0 R O I M R O I 2 M R O I 1 0 0 x m a x y m a x Figure 9 6 Decimation and MROI MAN085 04 2021 V1 3 67 of...

Страница 68: ...of the elongation of an injection needle is given in Fig 9 8 In this application the height information is less important than the width information Applying decimation 2 on the original image on the...

Страница 69: ...Corresponds to Vlow1 the higher the value the higher the compression Multislope_Time1 Time corresponding to kneepoint B The value is the fraction per mill of the total exposure time Multislope_Value2...

Страница 70: ...s e t K n e e p o i n t A K n e e p o i n t B M u l t i s l o p e _ T i m e 2 M u l t i s l o p e _ T i m e 1 E x p o s u r e T i m e Figure 10 1 Multi Slope Mode n u m b e r o f e l e c t r o n s S a...

Страница 71: ...for any available image dimensions and expsoure time settings ROI Dimension Standard MV4 D1280 L01 G2 MV4 D1280 L01 GT FB 1280 x 1024 SXGA 85 fps 935 fps 1024 x 1024 106 fps 1066 fps 1280 x 768 WXGA 1...

Страница 72: ...3 Frame rates of different ROI settings minimal exposure time for MV4 D1952 L01 cameras ROI Dimension Standard DR4 D1952 L01 G2 DR4 D1952 L01 GT FB 1952 x 1080 TBD fps 1000 fps 1920 x 1080 HD TBD fps...

Страница 73: ...a path The sequence of blocks is shown in figure Fig 12 1 From Image Sensor Receive logic Bad Pixel Correction Column FPN Correction Digital Gain Region LUT Binning Dual Crosshairs Test Images DR Comp...

Страница 74: ...ved working temperature 5 The image sensor must be uniformly illuminated to give an image with a mid grey level Check this before you proceed with the instructions 6 Set the visibility of the Device C...

Страница 75: ...on_Enable in category Photonfocus ColCorrection By default the correction is enabled 12 3 2 Calibration of the Column FPN Correction The Column FPN Correction of the camera is correctly calibrated at...

Страница 76: ...be done by clicking on the property ColCorrection_SaveToFlash in category ColCorrection Wait until the command has been finished i e the property ColCorrection_Busy category Correction ColCorrection i...

Страница 77: ...xt sections Two LUT and a Region LUT feature are available in the camera see Section 12 5 4 The LUT is implemented as a 12 to 8 bit LUT to be compatible with other Photon focus cameras Bits 0 1 of the...

Страница 78: ...ansfer curves 0 200 400 600 800 1000 1200 0 50 100 150 200 250 300 Grey level transformation Gain y 255 1023 a x x grey level input value 10 bit DN y grey level output value 8 bit DN a 1 0 a 2 0 a 3 0...

Страница 79: ...tor screens 0 200 400 600 800 1000 1200 0 50 100 150 200 250 300 Grey level transformation Gamma y 255 1023 x 1 x grey level input value 10 bit DN y grey level output value 8 bit DN 1 0 1 2 1 5 1 8 2...

Страница 80: ...UT 0 active in Region 0 X X X LUT 0 active in Region 0 and LUT 1 active in Region 1 LUT 0 supersedes LUT1 Table 12 1 LUT Enable and Region LUT When Region LUT feature is enabled then the LUTs are only...

Страница 81: ...y m a x L U T 1 x 0 0 x 1 0 x 0 1 x 1 1 y 1 0 y 0 0 y 0 1 y 1 1 Figure 12 7 Overlapping Region LUT example L U T 0 L U T 1 L U T 1 L U T 0 0 0 0 0 x m a x y m a x x m a x y m a x Figure 12 8 Region L...

Страница 82: ...side The result of the application of the Region LUT is shown on the right hand side One Region LUT was applied on a small region on the lower part of the image where the brightness has been increased...

Страница 83: ...binning 12 6 2 Camera settings The camera supports binning settings of 1 2 4 or 8 in horizontal and vertical direction The relevant parameters for binning are shown in Table 12 2 Property Type Descrip...

Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...

Страница 85: ...k 4095 means white This allows setting any grey level to get the maximum contrast depending on the acquired image Figure Fig 12 11 shows an example of two crosshairs with different grey values One wit...

Страница 86: ...e format settings are used in both situations The crosshairs however is set differently The crosshairs is not seen in the image on the right because the x and y position is set outside the ROI region...

Страница 87: ...ges 8 bit output left 10 bit output right 12 8 2 LFSR The LFSR Linear Feedback Shift Register test image outputs a constant pattern with a pseudo random grey level sequence containing every possible g...

Страница 88: ...histogram Fig 12 16 indicates problems that may be caused either by a defective camera by problems in the acquisition software or in the transmission path Figure 12 15 LFSR test pattern received and t...

Страница 89: ...hat the 12 bit format was chosen to be compatible with other Photonfocus cameras 12 9 2 Status Line Format If enabled the status line replaces the last row of the image with camera status information...

Страница 90: ...Value raw data without taking in account gain settings see Section 12 9 1 52 12 Horizontal start position of ROI OffsetX 56 12 Image Width 60 12 Vertical start position of ROI OffsetY In MROI mode thi...

Страница 91: ...280 L01 GT 525 MV4 D1280 L01 FB 528 DR4 D1280 L01 G2 526 DR4 D1280 L01 GT 527 DR4 D1280 L01 FB TBD MV4 D1952 L01 G2 534 MV4 D1952 L01 GT 535 MV4 D1952 L01 FB TBD DR4 D1952 L01 G2 TBD DR4 D1952 L01 GT...

Страница 92: ...e handled at all by an overload of interrupts To solve this issue the FrameCombine mode has been implemented in this camera In this mode the data of n images are bundled into one frame In the example...

Страница 93: ...w have the values 0xBB decimal 187 and 0x44 decimal 68 The remaining pixels of the filler rows have the value 0 An example is shown in Fig 12 19 The timeout occured after the second frame and the two...

Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...

Страница 95: ...st use camera power supplies which meet the Limited Power Source LPS requirements If you use a powered hub or a powered switch in PoE or USB vision systems these devices must meet the LPS requirements...

Страница 96: ...ge is available on the Photonfocus website www photonfocus com To ensure that the examples will work properly in your application you must adjust them to meet your specific needs and must carefully te...

Страница 97: ...lectronic parts Avoid the generation of ESD during cleaning Take only a small amount of detergent to clean the camera body Keep in mind that the camera body complies to the IP40 standard Make sure the...

Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...

Страница 99: ...ra Control Output Signal Output Power Single Ended 0 5 W ESD Contact Discharge Camera Control Signals 10 kV ESD Air Discharge Camera Control Signals 7 kV Fast Transients Bursts Data and Camera Control...

Страница 100: ...eIn0 LineIn1 LineIn2 Differential Input Voltage Logic Level Fault Condition VID 2V High No Fault 1 2V VID 2V High Indeterminate 0 9V VID 0 9V Indeterminate Low Differential Input Voltage Fault 2V VID...

Страница 101: ...the 17 pin M12 I O connector The MV4 10 GigE fibre cameras are interfaced to external components via an LC connector for multimode fibre through included SFP cage 10G fibre connector to transmit conf...

Страница 102: ...14 Hardware Interface Figure 14 2 Rear view of the MV4 10 GigE GT camera Figure 14 3 Rear view of the MV4 10 GigE fibre FB camera 102 of 151 MAN085 04 2021 V1 3...

Страница 103: ...iate voltages to your camera Incorrect voltages will damage the camera When using wall adapter an input voltage of 12V has a better efficiency in the internal power supply heat generation instead of s...

Страница 104: ...ion It pulsates when the camera is not grabbing images It means the intensity starts from dark and goes slowly to bright and slowly to dark again When the camera is grabbing images the LED blinks at a...

Страница 105: ...C0 R1 C1 R2 C2 10nF 10nF 3 4 5 6 7 8 9 Isolator 13 14 10 2 1 12 11 CAMERA_PWR CAMERA_GND ISO_GND 17 Isolator 17 pin M12 I O Connector Camera Firmware Camera Firmware LineOut0 LineOut1 LineOut2 17 pin...

Страница 106: ...TL Differential P and N input is available on the 17 pin I O connector when a dif ferential input standard is selected If a single ended I O standard is configured only the P input is available The N...

Страница 107: ...els and fault conditions Unused inputs should be configured as single ended and the N input must be tight to ISO_GND in order not to get an I O fault condition If an error condition has been detected...

Страница 108: ...O_GND TTL120 120 10nF 17 pin M12 I O Connector Camera Firmware Camera TTL or SE HTL YOUR_POWER YOUR_GND YOUR_GND R0 C0 R1 C1 R2 C2 YOUR_GND 3 4 5 6 7 8 9 2 1 12 11 17 ISO_IN0 ISO_IN1 ISO_IN2 ISO_IN3 Y...

Страница 109: ...configuration must be set to True in order to use the alarm indication Consider the polarity of the encoders Y ALARM signal The LineIn3 must be in verted when the Y ALARM signal is low active The Z si...

Страница 110: ...12 11 CAMERA_PWR CAMERA_GND ISO_GND 17 TTL120 120 10nF 17 pin M12 I O Connector Camera Firmware A B Z ALARM Encoder Camera YOUR_GND TTL or SE HTL R0 C0 R1 C1 R2 C2 GND ISO_IN0 ISO_IN1 ISO_IN2 ISO_IN3...

Страница 111: ...UR_POWER R R ISO_OUT0 ISO_OUT1 ISO_OUT2 high speed Figure 14 8 Example of output connection Respect the limits of the opto isolator in the connection to ISO_OUT Maximal ratings that must not be exceed...

Страница 112: ...T2 is used see connection B in Fig 14 10 which is a high speed TTL out put it can be connected to any of the four single ended input without a pull up resistor Isolator LineIn0 LineIn1 LineIn2 LineIn3...

Страница 113: ...rom camera power CAMERA_GND CAMERA_PWR Using a common power supply for camera and I O signals with star wiring 14 7 1 Separate Grounds To separate the signal and ground connections of the camera CAM_G...

Страница 114: ...ept Fig 14 13 shows a schematic of the star wiring concept applied to a Photonfocus GigE camera The power supply and ground connections for the camera and for the I O are connected to the same power s...

Страница 115: ...in this example is generated from a light barrier Note how the power and ground cables are connected to the same power supply ISO_IN Camera Flash ISO_OUT ISO_GND CAMERA_PWR CAMERA_GND Power Supply Li...

Страница 116: ...s a ground loop is shown in Fig 14 15 Isolator ISO_IN ISO_GND Ground Loop CAMERA_GND Ground plane voltage difference Connecting CAMERA_GND and ISO_GND the wrong way ground loop Figure 14 15 Improper I...

Страница 117: ...during storage and transport Please either retain this packaging for possible later use or dispose of it according to local regulations For long life and high accuracy operation we highly recommend to...

Страница 118: ...he mechanical drawing of the camera housing for the Photonfocus MV4 D1280 L01 GigE camera series 0 Figure 15 1 Mechanical dimensions of the Photonfocus MV4 D1280 L01 Luxima GigE cameras 0 Figure 15 2...

Страница 119: ...re 15 3 Mechanical dimensions of the Photonfocus MV4 D1280 L01 Luxima 10 GigE fibre cameras 0 Figure 15 4 Mechanical dimensions of the Photonfocus MV4 D1280 L01 Luxima 10 GigE ruggedized fibre cameras...

Страница 120: ...mechanical drawing of the camera housing for the Photonfocus MV4 D1952 L01 GigE camera series 0 0 Figure 15 5 Mechanical dimensions of the Photonfocus MV4 D1952 L01 Luxima GigE cameras 0 0 Figure 15...

Страница 121: ...re 15 7 Mechanical dimensions of the Photonfocus MV4 D1952 L01 Luxima 10 GigE fibre cameras 0 0 Figure 15 8 Mechanical dimensions of the Photonfocus MV4 D1952 L01 Luxima 10 GigE ruggedized fibre camer...

Страница 122: ...imensions of the MV4 C mount M42 adapter 0 J 0RXQW 81 Figure 15 10 MV4 C mount M42 adapter The adapter ring can be inserted by screwing it into the M42 mount of the camera front There are two screws o...

Страница 123: ...Mechanical dimensions of the MV4 C mount M42 adapter 0 J 0RXQW 81 Figure 15 13 MV4 C mount M42 adapter The adapter ring can be inserted by screwing it into the M42 mount of the camera front There are...

Страница 124: ...e ring is locked the lens can now be easily removed Figure 15 15 Position of the 2 small screws that lock C mount ring 15 3 Optical Interface 15 3 1 Cleaning the Sensor The sensor is part of the optic...

Страница 125: ...fulfil the above requirements and permanent damage to the sensor may result 4 Wipe the sensor carefully and slowly First remove coarse particles and dirt from the sensor using Q Tips soaked in 2 propa...

Страница 126: ...tips Hans J Michael GmbH Germany Methanol Fluid Johnson Matthey GmbH Germany Semiconductor Grade 99 9 min Assay Merck 12 6024 UN1230 slightly flammable and poisonous www alfa chemcat com 2 Propanol Is...

Страница 127: ...hotonfocus support support photonfocus com 16 1 1 No acquisition due to no triggers Set the camera to the free running trigger mode see Section C 1 1 If no images can be acquired in free running mode...

Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...

Страница 129: ...rial environments EN 61000 4 2 2009 Electronic discharge immunity tests EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field immunity test EN 61000 4 4 2012 Electrical fast...

Страница 130: ...s set out in Radio Interference Regulations 17 2 3 Pour utilisateurs au Canada Cet appareil est conforme aux normes Classe A pour bruits radio lectriques sp cifi es dans le R glement sur le brouillage...

Страница 131: ...sure that your warranty remains in force adhere to the following rules 1 Do not open the housing or destroy the warranty seal of the camera Touching internal electronic components of the camera may da...

Страница 132: ...ctions in the corresponding chapter of this manual 9 Transport and store the camera in its original packaging only and protect the sensor and the lens mount with a camera body cap 10 Read the manual c...

Страница 133: ...he Photonfocus sales team via email sales photonfocus com 19 2 Repair and obtaining an RMA Number Whenever you want to return a camera to Photonfocus contact first the Photonfocus support to be sure t...

Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...

Страница 135: ...20 References All referenced documents can be downloaded from our website at www photonfocus com MAN085 04 2021 V1 3 135 of 151...

Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...

Страница 137: ...voltages will damage or destroy the camera The connection of the input and output signals is described in Section 14 6 Suitable I O cables can be ordered from your Photonfocus dealership Connector Typ...

Страница 138: ...S422 HTL differential input negative polarity Single ended configuration Must be tied to ISO_GND 7 I ISO_INC2_P ISO_IN2 Differential configuration Isolated RS422 HTL differential input positive polari...

Страница 139: ...r A 2 GigE Connector An X coded M12 connector is used for the GigE interface and power supply of the camera Suitable GigE interface cables can be ordered from your Photonfocus dealership MAN085 04 202...

Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...

Страница 141: ...see Section 5 2 The timer active signal needs to be selected to output it on Line Out see Section 7 2 which has a fix delay of tlineout offset The Line Out is isolated by an opto isolator from the ca...

Страница 142: ...m for the timed exposure mode Timing Parameter Min Value Max Value tiso in 20 ns 165 ns tinput jitter 40 0 ns 53 3 ns tpulse delay 0 s 0 224 s texposure offset 80 0 ns 80 0 ns 1 time of 1 image row 18...

Страница 143: ...Camera runs in constant frame rate mode In some application it is necessary that the camera acquires image at a certain frame rate This mode is similar to the free running mode however a required fra...

Страница 144: ...ght software signals for instances SoftwareSignal0 A frame is started when the command TriggerSignalPulse in the section SoftwareSignalControl is applied SoftwareSignalSelector must be set to Software...

Страница 145: ...accordingly 8 The required image Width and Height must be set 9 The required PixelFormat must be set 10 AcquisitionMode must be set to Continuous 11 The software command AcquisitionStart must be appl...

Страница 146: ...tartReset must be set to False for the corresponding counter and the user must execute the parameter CounterReset manually for a first counter start C 3 2 Image Counter Any of the four available count...

Страница 147: ...ger or MissedTrigger 3 Parameter TimerTriggerActivation can be ignored This configuration is only necessary when Line0 input is selected as a trigger source 4 All other counter parameter must be left...

Страница 148: ...ction C 4 3 For every LUT value the following steps must be done 1 Set LUTIndex in category LUTControl to desired value The LUTIndex corresponds to the grey value of the 12 bit input signal of the LUT...

Страница 149: ...be connected to LineIn2 The Z signal can be used to reset the encoder 1 Configure the LineFormat of LineIn2 according to the encoder output standard 2 If the Z signal is used to reset the encoder the...

Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...

Страница 151: ...nformation about Multislope Mode Camera model MV4 D1952 L01 added 1 2 Mai 2020 Updated information about minimum exposure time frame rate of MV4 D1280 L01 GT FB slightly modifed 1 3 April 2021 Drawing...