
5 Counter & Timer
Acquisition End
Resets with the reception of the acquisition end event.
FrameTrigger
Resets with the reception of the frame trigger.
Frame Start
Resets with the reception of the frame start event.
Frame End
Resets with the reception of the frame end event.
Frame Burst Start
Resets with the reception of the frame burst start event.
Frame Burst End
Resets with the reception of the frame burst end event.
Exposure Start
Resets with the reception of the exposure start event.
Exposure End
Resets with the reception of the exposure end event.
User Output 0 ... 7
Resets the counter as long as the selected user output bit is asserted. The
counter remains in reset state until the selected user output bit is deasserted again (see
Section 4.7).
Counter 0 ... 3 Start
Resets with the reception of the chosen counter start event.
Counter 0 ... 3 End
Resets with the reception of the chosen counter end event.
Timer 0 ... 3 Start
Resets with the reception of the chosen timer start event.
Timer 0 ... 3 End
Resets with the reception of the chosen timer end event.
Encoder
Resets with the reception the encoder trigger event.
Action 0 ... 3
Resets with the reception of the chosen action signal event.
Software Signal Pulse 0 ... 7
Resets with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Resets when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally a activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Resets with the rising edge on the selected line input.
Falling Edge
Resets with the falling edge on the selected line input.
Both Edges
Resets with any edge on the selected line input.
Activation configuration has only effect when line input is selected as a counter
reset source, otherwise this configuration is ignored.
48 of 151
MAN085 04/2021 V1.3
Содержание Luxima DR4-D1280-L01-FB
Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...
Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...