5
Counter & Timer
5.1
Counter
C
o u n t e r
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R
i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
C o u n t e r
T r i g g e r
C o u n t e r
E v e n t
C o u n t e r
R e s e t
T i m e S t a m p
T i c k
C o u n t e r D u r a t i o n
C o u n t e r S t a r t V a l u e
C o u n t e r V a l u e
C o u n t e r S t a t u s
C o u n t e r R e s e t ( )
C o u n t e r V a l u e A t R e s e t
C o u n t e r A c t i v e
C o u n t e r S t a r t
C o u n t e r E n d
Figure 5.1: Counter Structure
Four general purpose counters are available (Counter0 . . . Counter3) which are used for
counting events. Each counter can be individually configured by software and controlled by
counter trigger, counter event and counter reset signals. This section describes the
configuration and the function of the counters.
Fig. 5.1 shows the structure of one counter. Along with the counter function itself it contains a
counter trigger source, a counter event source and a counter reset source selection and
activation block. Furthermore there is a counter active status signal, which is available in the
I/O control block (see Chapter 7). And the counter generates counter start and counter end
events, which can be used to trigger other blocks, like counter, timer, acquisition, frame or
exposure control.
5.1.1
Counter Usage
In a basic usage, at least a counter event source needs to be selected (see Section 5.1.5 for more
information about the counter event source selection). Once an event source has been
selected, the counter needs to be reset in order to start the counter. When started it counts
from a defined start value, which is configurable by the CounterStartValue property, and ends
counting events after a certain number of events, which is configurable by the
CounterDuration property.
MAN085 04/2021 V1.3
43 of 151
Содержание Luxima DR4-D1280-L01-FB
Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...
Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...